Instruction Manual Cast-It™ Gel CASTER 

VWR_v0617_E

 

1

 

WARRANTY 

VWR guarantees that the system you have received has been thoroughly tested and meets its published 
specification. 
 
However, immediately upon arrival, please check carefully that the shipment is complete and has not 
been damaged during transit. For missing parts or to report any kind of damage, please contact VWR 
(see 'TECHNICAL SUPPORT AND ORDERING INFORMATIONS'). Please retain all packaging materials 
until the delivery has been completely checked since this will speed up the return of goods if required 
and reduce environmental impact. Any form of returns, replacements or credit notes must be agreed in 
advance by VWR. 
 
For  the  complete  range  of  PerfectBlue

  electrophoresis  and  blotting  systems,  VWR  guarantees  a 

warranty  period  of  36  months  if  the  products  have  been  used  solely  according  to  the  instruction 
manual, if not agreed differently. No liability is accepted for loss or damage arising from incorrect use. 
VWR's  liability  is  limited  to  the  repair  or  replacement  of  the  unit or  refund of  the  purchase  price,  at 
VWR's  discretion.  VWR  is  not  liable  for  any  consequential  damages.  After  the  warranty  period  has 
expired VWR can offer repairs at low costs. 
 
VWR reserves the right to alter the technical specifications of the PerfectBlue

 electrophoresis or blotting 

systems without prior notice. This will enable us to implement developments as soon as they arise. 
 

PACKAGING LIST 

Unless differently agreed or marked on the delivery note the following items are included in shipment 
for the Cast-It™ Gel Caster:  
 

Casting base 
Center unit with side clamps 
2 casting cams 
2 gaskets for the center unit (red) 
2 gaskets on the casting base (black) 

 
When using the casting base the first time remove the plastic strips from the black gaskets. 
 
Note:    Glass  plates,  spacers  and  combs  are  not  included  in  the  shipment  and  should  be  ordered 

separately if needed! 

Summary of Contents for Peqlab Cast-It

Page 1: ...Instruction Manual Bedienungsanleitung Cast It Gel CASTER Cast It Gelgie stand...

Page 2: ......

Page 3: ...ruction Manual Cast It Gel CASTER VWR_v0617_E CONTENT WARRANTY 1 PACKAGING LIST 1 ASSEMBLING GEL PLATES FOR CASTING 2 BUFFERS AND SOLUTIONS 3 TROUBLESHOOTING 4 TECHNICAL SUPPORT AND ORDERING INFORMATI...

Page 4: ...to the instruction manual if not agreed differently No liability is accepted for loss or damage arising from incorrect use VWR s liability is limited to the repair or replacement of the unit or refund...

Page 5: ...hed glass plate side spacers and a blank glass plate Place the assembly onto one side of the center unit Slide the side clamps over the assembly and tighten the screws picture 2 DO NOT OVERTIGHTEN Pla...

Page 6: ...olution of electrophoresis buffer by dissolving 15 1 g Tris base and 94 g glycine in 900 ml of deionized H2O Add 50 ml of a 10 stock solution of SDS electrophoresis grade and adjust the volume to 1000...

Page 7: ...so wet silicone mats with e g water or buffer before placing the center unit onto the casting base to prolong their life span Skewed bands Gel has not polymerized properly at wells De gas gel solution...

Page 8: ...ment gaskets for upper buffer chamber S PEQL45 1010 GK Side clamps 2 side clamps for fixation of glass plates PEQL45 1010 CL Wing screws 2 wing screws for fixation of side clamps PEQL45 1010 WK Notche...

Page 9: ...cm wide 3 pieces PEQL45 1614 SD 0 8 mm 1 0 cm wide 3 pieces PEQL45 1614 SC volumes are calculated for a well length of 20 mm PerfectBlue Double Gel System Twin L Item Description Cat No Double gel sys...

Page 10: ...tched glass plate clear 20 x 10 x 0 30 cm PEQL45 2010 10R Blank glass plate clear 20 x 10 x 0 30 cm PEQL45 2010 10G Standard combs 1 5 mm 10 teeth 305 l PEQL45 2010 10D 1 5 mm 15 teeth 185 l PEQL45 20...

Page 11: ...anleitung Cast It Gelgie stand VWR_v0617_D 8 INHALT GARANTIE 9 LIEFERUMFANG 9 ZUSAMMENBAU DER GLASPLATTEN ZUM GIE EN 10 PUFFER UND L SUNGEN 11 TROUBLESHOOTING 12 TECHNISCHER SERVICE UND BESTELLINFORMA...

Page 12: ...d keine anderslautende Vereinbarung besteht Anspr che auf Ersatz oder Reparatur die aus einer fehlerhaften Verwendung entstanden sind werden nicht erf llt Die VWR GmbH verpflichtet sich zur Reparatur...

Page 13: ...s verbunden Entfernen Sie zum Gie en der Gele das Mittelteil aus der Gie basis Invertieren Sie die Gie basis Abbildung 1 Platzieren Sie das Mittelteil auf der invertierten Gie basis Die Aussparungen d...

Page 14: ...mM Glycin Elektrophoresegrad pH 8 3 0 1 SDS Bereiten Sie eine 5 x Stamml sung des Elektrophoresepuffers vor indem Sie 15 1 g Tris und 94 g Glycin in 900 ml deionisiertem H2O aufl sen F gen Sie 50 ml e...

Page 15: ...en Klebkraft auf der Gie basis sitzen und somit ohne Aufwand ab und aufgesetzt werden k nnen Bitte beachten Sie dass das Anfeuchten der Dichtungen mit Wasser oder Puffer vor dem Aufsetzen des Mittelte...

Page 16: ...Ersatzdichtungen 2 Ersatz Gummidichtungen f r Mittelteil S PEQL45 1010 GK Seitenklemmen 2 Seitenklemmen zum Befestigen der Gelplatten PEQL45 1010 CL Fl gelschrauben 2 Fl gelschrauben zum Fixieren der...

Page 17: ...St ck PEQL45 1614 SD 0 8 mm 1 0 cm breit 3 St ck PEQL45 1614 SC Taschenvolumen ist kalkuliert f r eine Taschentiefe von 20 mm PerfectBlue Doppelgelsystem Twin L Artikel Beschreibung Bestell Nr Doppel...

Page 18: ...ten Farbe klar Ma e B x L x D 20 x 10 x 0 30 cm PEQL45 2010 10R Glasplatte normal Farbe klar Ma e B x L x D 20 x 10 x 0 30 cm PEQL45 2010 10G Standardk mme 1 5 mm 10 Z hne 305 l PEQL45 2010 10D 1 5 mm...

Page 19: ...Bedienungsanleitung Cast It Gelgie stand VWR_v0617_D 16 NOTIZEN...

Page 20: ......

Reviews: