VWR 390-1351 Instruction Manual Download Page 38

Instruction Manual INCU-Line Premium Peltier Cooled

 

Page 

38

 / 

54

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Confirms and saves changes 

 

Cancels the entered changes 

 

 

 

In the field "lower alarm temp" you can set a value of -

1°C to - 5°C and in the field "upper alarm 

temp" you can set a value of +1°C to +5°C. 

 

5.18.  

 Network 

 

In this panel 

(Figure 42)

 you can change the settings for the network. Switch between the type of LAN / WiFi 

network, press the icon 

 or 

 

LAN settings 

(Figure 42)

 

 

IP

 

– the device’s IP address 

 

Mask

 

– an Ethernet network mask to which the device is connected  

 

Gate

 

– Server’s IP address or  router’s that manages the Ethernet network  

 

DNS

 

– IP address of the domain name system   

 

MAC

 

– the address of the network card, read-only 

 

DHCP

 

– you can select if the server that allocates IP addresses is running on the local network. You 

can then skip setting IP, Masks, Gates 

 

Only one type of network can be active. 

After changing the network type, it may be necessary to restart the device. 

Figure 41 - Alarm settings 

Summary of Contents for 390-1351

Page 1: ...Version 4 3 Issue 20 01 2022 Instruction manual VWR INCU Line Premium Peltier Cooled Incubators EU cat no IL 56PR Premium 390 1351 IL 112PR Premium 390 1352 IL 240PR Premium 390 1353 ...

Page 2: ...esponsibility to correctly dispose of your equipment at lifecycle end by handling it over to an authorized facility for separate collection and recycling It s also your responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of the equipment For more inform...

Page 3: ...11 5 4 User logging in 12 5 5 Main Screen 13 5 5 1 Alarm bar 14 5 5 2 Alarms panel 14 5 5 3 Information panel 15 5 5 4 Status description 16 5 5 5 Status protection and alarms 17 5 6 Programs 17 5 6 1 Program creating edition 18 5 6 2 Segments edition 19 5 6 3 Summary of segments 21 5 6 4 Loop 21 5 6 5 Priority 22 5 6 6 Protection class 22 5 7 Starting the program 23 5 8 Quick change of parameters...

Page 4: ...44 6 2 Access port 44 6 3 Open door alarm 45 6 4 Internal LED light 45 6 5 USB port 46 7 TEMPERATURE PROTECTION 47 8 REMOTE CONTROL OF THE UNIT 47 9 OPERATION OF THE COOLING SYSTEM 47 10 CLEANING AND MAINTENANCE OF THE UNIT 48 10 1 Exterior cleaning 48 10 2 Interior cleaning 49 11 ADVICE ON HOW TO SAFELY STORE THE UNIT 49 12 TROUBLESHOOTING 49 12 1 Possible defects 50 13 WARRANTY CONDITIONS 51 14 ...

Page 5: ...data 3 You should place samples in such a way to provide proper air circulation in the chamber open the door for the shortest period of time to reduce temperature fluctuations defrost the chamber if you open the door or store humid samples if possible do not store warm samples secure samples from being blown out by the chamber fan e g powdery samples always check that the doors are closed use only...

Page 6: ...struction manual and Premi um Control Software can be downloaded from internal memory on the USB Stick Description Quantity Cat No Additional stainless steel shelf for IL 56PR Premium 1 466 0454 Additional stainless steel shelf for IL 112PR Premium 1 466 0455 Additional stainless steel shelf for IL 240PR Premium 1 390 0967 Additional reinforced shelf up to 100 kg for IL 240PR Premium 1 390 1035 3 ...

Page 7: ...o level the unit after it has been placed in its final location The INCU Line 56PR and INCU Line 112PR models are stackable You can stack 2x IL 56PR 2x IL 112PR and you can also place the IL 56PR on top of the IL 112PR The IL 240PR models are not stackable The electric installation should meet the following conditions The electric installation should be secured by a 16 A ant surge fuse 3 1 Shelf i...

Page 8: ...board boxes sponges and other hygroscopic materials for storing the samples since they may increase the relative humidity in the chamber The unit has also been equipped with a drain for condensation water which may come from the modules of Peltier radiators This drain is positioned behind the fan plate The condensation water is collected in a con densate collection tray which is reachable from the...

Page 9: ... 2 point lock To close the door turn the handle to the verti cal position push the door gently then turn the handle to the horizontal position If the door has not been closed properly an alarm will sound Closing the door correctly reduces energy consumption and ensures proper temperature variation and fluctuation 3 5 Internal glass door To open or close the internal glass door use the plastic hand...

Page 10: ...or sensor 4 Internal LED light 5 Temperature sensor 6 Chamber fan 7 Key lock 8 Shelf 9 Internal glass door 10 Main power switch 11 Main power socket 12 LAN 13 Fan for electronic compartment 14 Access port 30 mm 15 Peltier cooling system 16 Height adjustable feet 4 DESCRIPTION OF THE UNIT 2 3 4 5 6 7 8 9 1 10 11 12 14 15 16 13 ...

Page 11: ...re and instruction manual on a USB stick Insert the USB Stick and wait a second to detect the hardware then press By pressing you quit downloading the folder the window will appear again during the next start You can tick Don t show again so that the window will not be dis played when you start You can always download the Download folder in the information panel More information page 34 5 3 Using ...

Page 12: ...t closing the keypad 5 4 User logging in Only the logged in User Super Admin or Admin can control the device If no User is logged in press in the main screen The login window will appear Figure 3 Login panel Factory default login parameters login admin leave the password field empty Super Administrator can create max 4 additional users More information in chapter 5 13 Sometimes input characters ca...

Page 13: ...5 5 Main Screen After switching on the device the Main Screen Figure 4 appears It contains the information about the de vice status To access to most functionalities the user should log in Figure 4 Main Screen Main Menu Start Stop the program Current temperature It is necessary to write down and remember the password because it is not possible to reset it If the password has been lost it is necess...

Page 14: ...User currently logged in Current date and time 5 5 1 Alarm bar The colour of the bar indicates the status of the device blue the device is working properly red alarm 5 5 2 Alarms panel In this place appears the list of alarms With active alarm the control bar is red The alarm event is displayed in the list with the status alarm active When an alarm event stops the alarm remains in the list as inac...

Page 15: ...e list that allows you to expand on the entire screen 5 5 3 Information panel You can view four different windows Switching between them is done by swiping your finger left or right Information about which window is active indicates Internal light is switched on Figure 7 Status icons Figure 5 Alarms panel Figure 6 Alarm details ...

Page 16: ...heating up to reach set temperature Set temperature is reached Icon is only visible when the chamber is cooling Icon is only visible when the chamber is heating 5 5 4 Status description The status of the device is indicated by description program name The name of program program user The name of user to whom the program belongs priority In regard of time or parameters more information can be found...

Page 17: ...e program parameters page 25 Information about protection classes page 49 In the right part there is information about the set alarms Alarms set page 40 Separately for overrunning up and down The value 0 means the alarm is turned off 5 6 Programs In this panel Figure 10 you can run the selected program add a new one edit the program delete it make it available to another user and download it from ...

Page 18: ...Name after pressing the keypad will appear and you will be able to enter the name of the program Segments number the number of segments max 100 segments per program Interval frequency of saving to data logging Protection class more information page 49 Protection temperature temperature range for the protection class Priority the priority of time or parameters more information page 24 Loop the numb...

Page 19: ...an over temperature protection 2 C time the time of maintaining the set temperature d hh mm days hours and minutes it is possi ble to select continuous work in the last segment ramp time the time of reaching the set temperature d hh mm days hours minutes The active value is highlighted in blue The item highlighted in red means that the value is out of range and you should enter another one eg the ...

Page 20: ...Instruction Manual INCU Line Premium Peltier Cooled Page 20 54 Figure 13 Program segment edition Figure 14 Program segment edition Figure 15 Program segment edition ...

Page 21: ...can scroll the panel up and down 5 6 4 Loop The option is available if the number of segments is equal to 2 or more When the program finishes the last segment the device starts the program again from the first segment You can define if a program should be carried out once loop 1 or multiple times loop 2 to 255 You can also set the program to be carried out continuously tick the option If a cycle r...

Page 22: ...alue measured by an independent temperature sensor the so called security sensor The main aim of the cartridge protection is to protect against uncontrolled rise or fall in temperature At the moment of activation the relay disconnects the heating cooling power supply Additionally the device is equipped with Class 3 3 over temperature protection when the temperature drops below the set protection v...

Page 23: ...er protection temperature 50 C the maximum temperature set in the segment that can be given is 48 More information see page 49 5 7 Starting the program You can start the program in two ways The first way Press the icon programs in main menu Figure 18 Then select the program you want to activate and press Start button Figure 19 Figure 19 List of programs Figure 18 Main menu ...

Page 24: ...gure 21 you have got two additional options Immediate start of the program Scheduled program start according to the set date and time 5 8 Quick change of parameters You cannot make a quick change time temperature in a running program belonging to another user Information about the program owner can be found on the bottom panel Figure 8 Figure 20 Main screen Figure 21 Starting the program ...

Page 25: ...perature under temperature 2 C and higher than protec tion temperature over temperature 2 C 5 8 2 Quick change the set time In order to quickly change the duration time of the program press the icon in main screen Figure 4 Select the number of days hours and minutes by scrolling the list up or down Figure 23 Confirm the change by pressing To set the continuous work press To change the way of displ...

Page 26: ...re C the highest recorded temperature Average temperature C average temperature Segment status of the segment In progress currently performed segment data is constantly updated finished the segment is made interrupted the segment was interrupted by the User before the set time expired Segment 1 2 the number of the currently overviewing segment number of the currently performed or completed segment...

Page 27: ...egate data according to the selected column To do so click the column heading Data are only registered when the program is running The frequency of registration depends on the program parameters settings The time of opening the Data Register depends on the number of saved data The larger num ber of stored cells increases the opening time of the window Then a progress window will appear Figure 25 i...

Page 28: ...ith a spreadsheet plkx opening with the Premium Control application Diagram display see page 31 Deleting data Users with Super Admin rights can delete all data also those regis tered by other users Figure 27 5 10 1 Graph It is possible to generate a graph Figure 28 from the available samples in the data register Figure 26 Data Register Figure 27 Deletion of data ...

Page 29: ...graph depends on the number of saved data The larger number of stored cells increases the opening time of the window It is possible to enlarge a fragment of the graph Press anywhere and swipe both right and down at the same time Figure 29 By swiping to the left you can back to the normal size of the graph Figure 28 Temperature graph Figure 29 Enlarging the graph ...

Page 30: ...in switch Device Off the device is switched off on the main switch Door closed the door is closed Door opened the door is opened Open door alarm start open door alarm has been activated Open door alarm stop open door alarm has been deactivated Over Protection Start over temperature protection has been activated Over Protection Stop over temperature protection has been finished Program Edit changin...

Page 31: ...eted Deleted All Measurement all measurements have been deleted User added new user has been added User updated user has been changed User deleted user has been deleted Program saved new program has been saved Program deleted program has been deleted Program updated program has been updated 5 12 Info The panel contains the following information Software versions name of the unit manufacturer s add...

Page 32: ... offline program in the Premium Control application 5 13 Users In this panel Figure 33 the Super Administrator can add a new user edit an existing one or delete it Max 5 different users can be created and max 40 programs can be freely distributed among these 5 users Add a new user Edit the selected user Delete the selected user along with the user his programs and data register will be also delete...

Page 33: ...rs Should be given login a user name password account password password confirmation enter the password again to confirm it type type of account Super Admin and Admin Users have only access to type account Admin More information in chapter 5 14 programs limit the number of programs that user can create the number of available programs Confirms and saves the user Cancels the entered data and return...

Page 34: ...escribed below Admin account It has access to program management menu where users can create or edit programs programs check their statistics statistics and data register and information about the system info Super Admin account Super Admin account has not limits It has access to the program menu management and to the settings menu Figure 35 Main menu Admin Figure 36 Main menu Super Admin ...

Page 35: ...5 15 Interface In this panel Figure 39 you can Change the language of device Set the time after which the screen will be dimmed Turn on off the sound alarm sounds will be still emitted Set the time after which the user will be automatically logged out Figure 37 Main menu Super Admin Figure 38 Main menu Super Admin ...

Page 36: ...ged while the program is running If you change the date and time to an earlier than the current one a message will appear on the display Changing the date time will interfere with the records in the database Delete the data from data record and event log first then change the date time You must first delete the data from the data record and from event log and then change the date time Confirms and...

Page 37: ...rature drops below the value given in this field upper alarm an alarm will be generated if the temperature rises above the value given in this field The lower and upper alarm can only be generated after reaching the set temperature delay exceed alarm the alarm will be activated with a delay 1 min 2 min 5 min 15 min after exceeding the permitted temperature delay door alarm the door alarm will be a...

Page 38: ...network press the icon or LAN settings Figure 42 IP the device s IP address Mask an Ethernet network mask to which the device is connected Gate Server s IP address or router s that manages the Ethernet network DNS IP address of the domain name system MAC the address of the network card read only DHCP you can select if the server that allocates IP addresses is running on the local network You can t...

Page 39: ...Confirms and saves changes Cancels the entered changes WiFi settings Figure 43 press to refresh network list SSID press to select network from the drop down list PSK network password IP Mask Gate DNS automatically completed when the network connection is correct MAC the address of the network card read only A A Figure 42 LAN settings ...

Page 40: ...ypes for which notifications should be sent Figure 44 Activate activate or deactivate e mail notifications Door alerts alarms caused by the half open door Critical alerts critical alerts e g sensors damage Temperature alerts alarms caused by too high or too low temperature Programs events connected with programs e g adding edition delete of a program Users events connected with users edition setti...

Page 41: ...t be sent Sender and recipients Figure 45 Sender sender s e mail address Recipients recipient s e mail addresses up to 3 Confirms and saves changes Cancels the entered changes Configuration of the sender e mail account Figure 46 In this window you can add the details of your e mail account Server ID SMTP Server password SMTP Server Host SMTP Server Port SMTP Figure 45 E mail sender and recipients ...

Page 42: ...correction value is taken in the whole temperature range operation of the device For example if the average tempera ture displayed by the device indicates 37 C and the average temperature measured by independent external sensor indicates 37 5 C the correction should be set on 0 5 C The average temperature should be calculated from chosen period of time e g 30min The correction range of 5 C to 5 C ...

Page 43: ...orresponds with a great accuracy to the temperature in the geometrical centre of the chamber For the correct operation of the unit it is not necessary to use User s calibration The user is performing temperature correction on his own responsibility and he must be aware of consequences of changing of manufacturer s settings If the equipment was calibrated calibra tion certificate loses its validity...

Page 44: ...ess port A Ø30 mm access port can be used to insert an external temperature sensor which has been secured with a silicon plug The plug should cover the access port while the unit is operating If multiple cables have been inserted through the access port and if it is not possible to use the plug secure the access port with adhesive tape If you leave the access port open it may affect temperature st...

Page 45: ... the selected delay door alarm time an alarm will sound and the control bar will be red The alarm event door open is displayed in the list with the status alarm active 6 4 Internal LED light All incubators have been equipped with internal LED lighting Philips Corepro LEDspot 3 5 35W GU10 827 36D which switches on when opening the door Once the light has been switch on a bulb icon will appear on th...

Page 46: ...SB slot on the device Go to Setup Data record press the button Select file type csv plkx Press Data is copied Data saved as csv file can be opened in the Notepad Data saved as plkx file can be opened only by Premium Control This program allows you f ex to view the data in the table as a graph It allows you to make a report of selected data range Figure 48 export saved data ...

Page 47: ...ature returns to within normal pa rameters the device continues to work normally 8 REMOTE CONTROL OF THE UNIT Every Premium unit can be connected to the Ethernet network and controlled remotely using the Premium Control software The features of the program have been described in a separate instruction manual 9 OPERATION OF THE COOLING SYSTEM The thermoelectric incubator relies on Peltier effect Co...

Page 48: ...are incubated in the chamber In such case we recommend using cleaning solution to clean the stains which is dedicated to this particular application e g Pelox 10 1 Exterior cleaning 1 The housing and door should be cleaned with caution using a soft cloth dampened with water 2 Only mild cleaning products should be used to clean the device 3 Electrical parts should not be in contact with water or de...

Page 49: ... 4 Leave the door open to allow adequate ventilation 5 Store in temperatures between 0 C and 50 C and relative humidity maximum 70 12 TROUBLESHOOTING Before you contact VWR Service Department 1 Make sure that the operation complies with the instruction manual of the device 2 Restart the device to make sure that the unit is not functioning properly If it still does not work disconnect the unit agai...

Page 50: ...en Change the cable The unit is not cooling down Check if the unit is exposed to direct sunlight Change the location of the unit Check if the unit is located near a radiator Change the location of the unit Check if the door of the unit is closed properly Clean the gasket Does the installation site meet the installation conditions Adapt to the installation re quirements on site according to point 3...

Page 51: ...ccording to the manuals and any local regulations such warranty turns invalid except to the extent the defect of the product is not due to such non performance Items being returned must be insured by the customer against possible damage or loss This warranty shall be limited to the aforementioned remedies IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN...

Page 52: ...IFICATION LABEL The product identification label is located on the left upper corner of the unit An example of the rating plate 1 Logo 2 Type of the unit 3 Catalogue number 4 CE mark 5 Name and address of the manufacturer 6 Serial number 7 Bar code and UK importer 1 2 3 4 5 6 7 8 ...

Page 53: ...h 690 780 840 Internal dims mm D width 400 460 600 E height 390 540 800 F depth 350 440 510 Max shelf workload kg 25 25 25 Max unit workload kg 50 50 90 Nominal power W 500 650 800 Weight kg 53 71 116 Temperature fluctuation2 at 37 C C 0 1 0 1 0 1 Temperature variation3 at 37 C C 0 2 0 2 0 3 Powers supply 230V 50Hz Energy consumption at 10 C Wh 1h 65 99 137 Energy consumption at 37 C Wh 1h 45 77 1...

Page 54: ...Orion Business Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VW R International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 Email info it vwr com Korea VW R International 17 Daehak 4 ro Yeongtong gu Suwon si Gyeonggi do Tel 82 31 645 7256 saleskorea avantorsciences com Middle East Africa VW R International FZ LLC DSP Laboratory...

Reviews: