background image

 

 

 

 1 

 

 

 

VUTEC CORPORATION 

www.vutec.com 

TEL: (954)-545-9006 

FAX: (954)-545-9011 

EMAIL: [email protected] 

02/20/08 – 06/10 Rev. D 

2-INSTL_D 

 

IMPORTANT SAFETY INSTRUCTIONS 

Basic safety precautions should always be followed; including the following: 

 

Read and understand all instructions before proceeding with the installation and operations. 

 

Lectric 2 and Lectric 4 meet requirement for fire-resistant and low smoke-producing 
characteristics suitable for operation in a building’s environmental air space, such as above 
suspended ceilings, in accordance with Section 300-22 (C) of the national Electric Code, 
ANSI/NFPA 70, and sections 2-128, 12-010(3) and 12-100 of the Canadian Electric Code, Part 1, 
CSAC22.1.  

 

Be certain that the supporting structure is sound and capable of carrying the weight as required. 

 

Seek qualified electricians to perform electrical requirements. 

 

This permanently connected projection screen must be protected by a fuse or circuit breaker. 
Make sure that there is a readily disconnect device incorporated on the building installation 
wiring. 

 

Obtain proper lifting mechanism to raise and hold the unit steady for installation. 

 

Plan ahead so the installation can go smoothly and efficiently. 

 

IMPORTANT

 

WARNINGS

 

AND

 

CAUTIONS!

 

 

WARNING:

 

A

 

WARNING

 

ALERTS

 

THE

 

POSSIBILITY

 

OF

 

SERIOUS

 

INJURY

 

OR

 

DEATH

 

IF

 

THE

 

INSTRUCTIONS

 

ARE

 

NOT

 

FOLLOWED.

 

 

CAUTION:

 

A

 

CAUTION

 

ALERTS

 

THE

 

POSSIBILITY

 

OF

 

DAMAGE

 

OR

 

DESTRUCTION

 

OF

 

EQUIPMENT

 

IF

 

THE

 

INSTRUCTIONS

 

ARE

 

NOT

 

FOLLOWED.

 

 

WARNING:

 

FAILURE

 

TO

 

READ,

 

THOROUGHLY

 

UNDERSTAND,

 

AND

 

FOLLOW

 

ALL

 

INSTRUCTIONS

 

CAN

 

RESULT

 

IN

 

SERIOUS

 

PERSONAL

 

INJURY,

 

DAMAGE

 

TO

 

EQUIPMENT,

 

OR

 

VOIDING

 

OF

 

FACTORY

 

WARRANTY!

 

IT

 

IS

 

THE

 

INSTALLER’S

 

RESPONSIBILITY

 

TO

 

MAKE

 

SURE

 

ALL

 

COMPONENTS

 

ARE

 

PROPERLY

 

ASSEMBLED

 

AND

 

INSTALLED

 

USING

 

THE

 

INSTRUCTIONS

 

PROVIDED.

 

 

WARNING:

 

FAILURE

 

TO

 

INSTALL

 

ELECTRICAL

 

REQUIREMENTS

 

ACCORDING

 

TO

 

NATIONAL/LOCAL

 

ELECTRICAL

 

CODES

 

AND

 

REGULATIONS

 

MAY

 

CAUSE

 

PREMATURE

 

FAILURE,

 

FIRE

 

HAZARD,

 

ELECTRICAL

 

SHOCK,

 

UNSAFE

 

PRACTICE

 

AND

 

REVOCATION

 

OF

 

USE.

 

DISCLAIMER

 

Vutec Corporation intends to make this manual accurate and complete. However, Vutec makes no claim that the 
information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency 
in connection with the installation for use of this product. The information contained in this document is subject to change 
without notice. Vutec makes no representation of warranty, expressed or implied, regarding the information contained 
herein. Vutec assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this 
document. 

PRE- INSTALLATION 

1)

 

Carefully cut and remove packing materials. 

2)

 

Carefully unpack and inspect the unit for sign of damages. 

3)

 

Be sure to recheck and measure all pertinent dimensions before installation. 

4)

 

Most basic tools are required for installation. 

 

SAVE THESE INSTRUCTIONS 

Summary of Contents for Lectric 2

Page 1: ...20 08 06 10 Rev D 2 INSTL_D VUTEC CORPORATION www vutec com TEL 954 545 9006 FAX 954 545 9011 EMAIL info vutec com Installation Instructions Lectric 2 4 FLUSH CEILING MOUNT SCREEN FULL TRAP DOOR CLOSU...

Page 2: ...OLLOWED CAUTION A CAUTION ALERTS THE POSSIBILITY OF DAMAGE OR DESTRUCTION OF EQUIPMENT IF THE INSTRUCTIONS ARE NOT FOLLOWED WARNING FAILURE TO READ THOROUGHLY UNDERSTAND AND FOLLOW ALL INSTRUCTIONS CA...

Page 3: ...1 EMAIL info vutec com 02 20 08 06 10 Rev D 2 INSTL_D LECTRIC 2 4 FLUSH CEILING MOUNT WITH TRAP DOOR SELF SUPPORTED shown and TAB TENSIONED screens Figure 1 SCREEN TYPE LENGTH DIM A SELF SUPPORTED VIE...

Page 4: ...ced on top of this flange to provide a finished appearance WARNING SUPPORTING STRUCTURE MUST BE CAPABLE OF CARRYING 4 TIMES THE UNIT WEIGHT CHECK WEIGHT DATA AT THE END OF THIS DOCUMENT Threaded rods...

Page 5: ...Section for instructions CAUTION BE SURE TO PLACE THE CONNECTING WIRES INSIDE BEFORE PROCEEDING WITH THE HOUSING INSTALLATION Install the housing once the screen roller assembly is removed Be sure th...

Page 6: ...onnect the switch from the pigtail Loosen the screw of the electrical cover Figures 5a and 5b Remove the cover to gain access to the electrical compartment The cover may remain inside the housing Pull...

Page 7: ...TO THE SCREEN IF IT IS ALLOWED TO COME DOWN BELOW LEADER REQUIREMENT Verify the leader requirement for the installation Send the screen down and expect it to stop at the leader requirement Stop if the...

Page 8: ...HE WARRANTY The second upper limit for the screen is set by the motor limit switch Yellow button or Yellow hex socket If the screen missed the hooks of the trap door it should come up close the screen...

Page 9: ...nd expect the screen to move down 3 4 inch If the screen did not move turn the hex socket two full turns in the opposite direction counter clockwise and expect the screen to move down 3 4 inch Determi...

Page 10: ...the screen Referring to Figures 5a and 5b open the electrical cover plate and pull down the wire nuts bundle Disconnect wires from all wire nuts Use a 5 16 hex key to disconnect motor ground form top...

Page 11: ...ng components removed to illustrate details WEIGHT DATA Some standard viewing sizes are shown Extrapolate the information for size not showing as necessary or contact Vutec for details Divide lbs by 2...

Page 12: ...r hums a Check breaker fuse b Check wall switch c Push button limit switches might be tripped d Thermal overload tripped e Defect4 motor or wall switch f Temporary binding g Capacitor burned out a Rep...

Reviews: