TEMPERATURE PROBE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
NOTE:
If right side - front panel is not accessible, this
component can be serviced by removing CONTROL
PANEL.
2.
Disconnect the probe leads (1, Fig. 9) from the
solid state temperature control.
Fig. 9
3.
Remove the racks from inside cavity.
4.
Remove the probe guard.
Fig. 10
5.
Remove probe by pushing it through the oven
wall opening (2, Fig. 9) in control panel area.
6.
Reverse the procedure to install the replacement
probe.
7.
Adjust the temperature control. Refer to: SOLID
STATE TEMPERATURE CONTROL TEST .
HEATING ELEMENTS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE - REAR PANEL.
2.
Disconnect element wire connectors.
Fig. 11
3.
Remove racks from cavity.
4.
Remove FAN COVER.
Loosen element screws on side wall.
5.
Remove screws on back wall holding brackets.
VC5ED FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
F45652 (0217)
Page 8 of 31