FULL SIZE GAS CONVECTION OVENS - CONDENSED SPARE PARTS LIST
CODE & PROBLEM
PROBABLE CAUSE
SOLUTION
F24682 (Rev. B, October 2007)
Printed in U.S.A.
Er06 - Zone 1 A/D underflow
error
• Incorrect sensor type
• Measuring temperature outside the
sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor. If the
condition causing the error is
resolved, the error will clear.
Er07 - Zone 1 A/D overflow
error
Open sensor
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor. If the
condition causing the error is
resolved, the error will clear.
Er10 - Stack overflow error
Microprocessor malfunction
• Cycle power.
• Check sensor and connections for a
reversed or open sensor.
Er11 - Open sensor error
Open sensor
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor.
Er12 - Shorted sensor
• Incorrect sensor type
• Measuring temperature outside the
sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections for a
reversed or open sensor.
Summary of Contents for VC4GC
Page 57: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 57 of 68...
Page 59: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 59 of 68...
Page 61: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 61 of 68...
Page 63: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 63 of 68...
Page 65: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 65 of 68...