FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
F24682 (Rev. B, October 2007)
Page 28 of 68
B.
If doors operate properly, continue with
procedure.
7.
Install the lower front cover.
COMPUTER CONTROL
(VC4GC/VC6GC)
Operation
Refer to the Instructions Manual for specific
operating instructions.
Setup Mode
NOTE:
Use the setup mode to verify that the control
is configured to the factory settings which result in
the proper operation of the oven. If the CAL1
parameter is other than zero, determine if it is still
needed before resetting to zero. See COMPUTER
CONTROL CALIBRATION (VC4GC/VC6CG).
Changing the C_F, InP1, rL1 & rH1
parameters will default all menus.
1.
Use this key sequence to access the setup
mode.
Up arrow; Rack 1; Temperature; Temperature;
Down arrow; Rack 1
2.
Once in the setup mode the display will
alternate between the parameter and
programmed data.
•
To change data to the factory setting, use
the arrow keys.
•
To select the next parameter, press the
Rack 1 key.
•
After the last Parameter and Data is
viewed, press the Rack 1 key a final time
to exit the setup mode and return to
operations mode. The current set point
temperature will be displayed.
•
After 1 minute of no key activations, the
control will return to operation mode.
3.
Listed are the parameters and data you should
find.
MENU
ALTERNATING ON
DISPLAY
PARAMETER
DATA
Celsius_Fahrenheit
C_F
F
Guard Band
gb
4000
Temperature
Compensation
tcnP
OFF
Input Type 1
InP1
J
Range Low 1
rL1
75
Range High 1
rH1
500
Hysteresis
HYS1
3
Calibration Offset
CAL1
0
Exit Setup Mode and
return to Operation
Mode.
set point temperature is
displayed or if call for
heat, dashes (----)
displayed.
Probe Test
1.
Set the control to 350
E
F.
2.
Access the back of the control panel to
disconnect the probe lead wires.
3.
Install a jumper wire across the probe terminals.
This will simulate room temperature.
A.
If the heat light comes on and the actual
temperature is room temperature, replace
the probe.
B.
If the heat light does not come on or the
actual temperature is not room
temperature, replace the control.
Solid State Relay Test
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
2.
Set the temperature to 350°F or high enough to
keep the heat ON for several minutes.
3.
Check for +5 VDC on input side of SSR
(terminals 3 & 4).
A.
If +5 VDC is present, continue to step 4.
B.
If no voltage is present, computer control is
not functioning properly.
4.
Check for 120 VAC at load side of SSR
(terminals 1 & 2).
A.
If no voltage is present, solid state relay is
not functioning properly.
1)
Replace the SSR and check for
proper operation.
B.
If 120 VAC is present, component is
functioning properly.
Summary of Contents for VC4GC
Page 57: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 57 of 68...
Page 59: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 59 of 68...
Page 61: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 61 of 68...
Page 63: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 63 of 68...
Page 65: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F24682 Rev B October 2007 Page 65 of 68...