Vulcan-Hart VBB1BF Service Manual Download Page 8

Fig. 11

4.

Reverse procedure to install and check for proper
operation.

CERAMIC-RADIANT BURNER

 Shut off the gas before servicing the

unit.

1.

Remove MANIFOLD COVER.

2.

Remove CONTROL VALVE COVER next to rack
lift assembly handle.

3.

Adjust rack assembly to the lowest position to
access the burners.

 Ceramic bricks can easily be damaged.

Use care when handling.

4.

Lift ceramic bricks [1] Fig. 12 off the support rails
[2] Fig. 12 for each burner [3] Fig. 12. There are
6 ceramic bricks for each of the 3 burners (18
bricks total).

Fig. 12

5.

Remove screws securing pilot tube mounting
brackets [1] Fig. 13 to burner support [2] Fig.
13
. Position pilot tube assemblies out of the way
to the sides.

Fig. 13

6.

Remove screws securing manifold bracket [1]
Fig. 14 to burner support [2] Fig. 14. Allow
bracket to drop down out of the way.

Fig. 14

7.

Loosen screws [1] Fig. 15 (qty 6) by several turns
that secure the burner support [2] and brace [3]
Fig. 15 to broiler frame.

V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - REMOVAL AND

REPLACEMENT OF PARTS

F45548 (0715)

Page 8 of 16

Summary of Contents for VBB1BF

Page 1: ...tools instruments and skills required to perform the procedure Procedures for which you do not have the necessary tools instruments and skills should be performed by a trained Vulcan Service Technici...

Page 2: ...BURNER 8 INFRARED BURNER 10 GAS PRESSURE REGULATOR 10 RACK SPRINGS 10 SERVICE PROCEDURES AND ADJUSTMENTS 12 PILOT FLAME HEIGHT 12 CERAMIC RADIANT BURNER AIR SHUTTER ADJUSTMENT 12 REGULATOR ADJUSTMENT...

Page 3: ...ers Operations Manual sent with each unit The manual is also available online at www vulcanequipment com RACK POSITION AND GAS SETTING NOTE Infrared burner models must use the full gas setting knob fu...

Page 4: ...lly Assemble the parts and retain for future use on gas equipment Pipe tee sized for the gas line inlet connection and pipe fittings pipe nipples reducers etc for the connection as required Hose barb...

Page 5: ...must be checked for leaks Check with a soap and water solution bubbles Do not use an open flame Accessing Control Valve Upper Broiler double stack or single unit over range The side panel must be remo...

Page 6: ...ews at the rear that are securing the back panel 1 Fig 6 and side panel to broiler frame Arrows shown in Fig 6 are pointing to the rear screw locations for right side panel removal Fig 6 D Remove side...

Page 7: ...ilot tube fitting and remove the tube Fig 9 When disconnecting compression nut from the pilot tube fitting support the fitting to prevent damage to pilot tubing 5 Reverse procedure to install and chec...

Page 8: ...ach burner 3 Fig 12 There are 6 ceramic bricks for each of the 3 burners 18 bricks total Fig 12 5 Remove screws securing pilot tube mounting brackets 1 Fig 13 to burner support 2 Fig 13 Position pilot...

Page 9: ...nto the broiler grid Position 2 x 4 s underneath the burners near the front Fig 18 11 Adjust rack assembly to the middle position 12 Remove cotter pin from all three burners Fig 19 13 Grasp the bottom...

Page 10: ...flame Clean pipe threads and apply thread sealant that is suitable for use with propane gases NOTE Gas pressure regulator should be installed as close to the broiler inlet gas connection as possible 1...

Page 11: ...n springs Fig 24 3 Remove springs from the lifting arm mechanism and eye bolt 4 Reverse procedure to install 5 Perform RACK SPRING TENSION ADJUSTMENT V SERIES HEAVY DUTY BROILERS DOUBLE DECK AND RANGE...

Page 12: ...stics and excessive gas consumption may occur An air shutter on the front of the burner controls the gas mixer balance A yellow streaming flame on the burner is an indication of insufficient primary a...

Page 13: ...wise to decrease pressure until the proper gas pressure is achieved C Install the regulator closing nut D Turn gas supply off E Remove manometer and tee from gas line Clean pipe threads and apply thre...

Page 14: ...base of the valve stem See LUBRICATION If valve grease does not improve rotation of the valve or damage is found replace the CONTROL VALVE as outlined under REMOVAL AND REPLACEMENT OF PARTS RACK SPRIN...

Page 15: ...gas pressure 3 Control valve malfunction CERAMIC RADIANT BURNER CERAMIC RADIANT BURNER SYMPTOM POSSIBLE CAUSE Flame too yellow 1 Orifice incorrect size or dirty 2 Air shutter not adjusted correctly o...

Page 16: ...r not lighting properly or incorrect burner flame appearance due to clogged ports 1 Broiler with Infrared burner is located too close to a fryer or charbroiler and the grease laden air is causing burn...

Reviews: