– 27 –
WARNING: DISCONNECT (UNPLUG) ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH INDICATING YOU ARE WORKING ON THE CIRCUIT.
1. Remove the blower motor and mounting assembly as outlined under Blower and Motor in Removal and
Replacement of Parts.
2. Loosen the motor mounting bolts.
3. Adjust the motor position until the blower is parallel to and
1
/
4
" inch away from the motor mounting plate.
Check to see if the blower is square to the motor mounting plate at the top, bottom, left and right of the
blower.
A. If the blower is square, then tighten motor mounting bolts and proceed to step 4.
B. If the blower is not square, continue adjusting until proper spacing is achieved then tighten motor
mounting bolts. If necessary, place shims between motor and frame.
4. Reverse the procedure to install. Use locktight on mounting nuts and bolts.
BLOWER ADJUSTMENT
MOTOR MOUNTING PLATE
PLACE SHIMS UNDER FRONT OF
MOTOR TO WIDEN BOTTOM SPACE.
PLACE SHIMS UNDER REAR OF
MOTOR TO WIDEN TOP SPACE.
BOTTOM
TOP
PLACE SHIMS HERE
WHEN NEEDED.
FLAT
WASHER
MOTOR
FRAME
FLAT WASHER
NUT/STAR
WASHER
1/4 INCH AT
ALL PLACES
BLOWER
PL-56058
Summary of Contents for SG4C ML-114876
Page 2: ...2 VULCAN HART COMPANY 2002...
Page 38: ...38 WIRING DIAGRAMS WIRING DIAGRAM SG4D SG6D OVENS 120 200 V 424372 Rev F...
Page 39: ...39 WIRING DIAGRAM 734 COMPUTER CONTROL DUAL BURNER CONVECTION OVENS 120 200 V 426574 Rev C...
Page 40: ...40 SCHEMATICS GAS CONVECTION OVEN SG4 WITH STD CONTROL 424373 1 REV C...
Page 41: ...41 GAS CONVECTION OVEN SG4 WITH WATLOW 734 CONTROL 426575 1 REV C...