background image

[  12  ]

REV4-11-2011  /  VFM06

©  copyright subsists on all work published in this operating manual and may not be reproduced or adapted, 

in whole or in part, without written permission of Vulcan catering Equipment (Pty) Limited. Whilst every effort 

has  been  taken  in  the  preparation  of  this  operating  manual  to  ensure  the  accuracy  and  relevance  of  the 

contents, Vulcan catering Equipment (Pty) Limited cannot be held responsible for any omissions or errors, or 

from damages resulting from the use of information contained herein. 

VULCAN GAS RANGES RG-6 OPEN BURNER

Subject to standard Vulcan warranty within South africa borders. Subject to standard Vulcan Export warranty outside South africa 

borders. Vulcan reserves the right to modify or alter appliances without prior notice. Local prices subject to confirmation at time 

of purchase / placing of order.

WARNING

This is an un-vented gas appliance.  It uses air (oxygen) from the room in 

which it is installed.  Provisions for adequate ventilation must be provided.

VULCAN CATERING EQUIPMENT (PTY)LTD

Burners: Open Top:  

Lift the cast iron grate and spider and observe the flame, it should be a soft blue flame, 

showing no yellow, if the flame is harsh or has yellow tips correct this by adjusting the 

air intake of the burner.
To reach the air adjustments, open the access panel above the oven, a 6mm Hex locking 

screw  should  be  unscrewed  slightly  and  the  adjusting  sleeve  moved  to  the  optimum 

position then the screw tightened again. 

DO NOT

 over tighten the locking screw. The 

above procedure should be followed for all burners.

SAFETY:

1.   Remember  to  always  use  extreme  caution  when  dealing  with  any  heavy  duty  

gas appliance.

2.   Always  ensure  that  the  pilot  flames  are  properly  ignited  before  opening  the 

 

gas valves.

3.   always check that the gas controls are switched off after use.
4.   do not leave the unit unattended whilst lit.
5.   do not move the appliance whilst lit.

6.   Do not place or use flammable materials near unit.
7.   Do  not  tamper  with  any  parts  sealed  by  manufacturer.  Any  modification  of  this 

appliance  is  dangerous  and  will  nullify  any  warranty.  all  repairs  or  adjustments 

should be made by a qualified technician.

8.   Turn off the gas supply at the main gas after use. 
9.   This appliance consumes oxygen and it is dangerous to human health and safety of 

humans. use only in well ventilated areas. 

Summary of Contents for RG-6

Page 1: ...an catering Equipment Branches and dealers 3 Parts Ordering Service Information 4 Prior to Installation of Equipment 4 Heat Settings 4 cleaning Process 4 Trouble Shooting 5 Installation 5 Operation 6 Line drawing 8 Spares 9 Preventative Maintenance 10 Safety 12 VULCAN GAS RANGES RG 6 OPEN BURNER ...

Page 2: ...quipment Dealer for replacement Important Information For The User This appliance may only be installed by a registered LP Gas installer All registered installers are issued with a card carrying their registration number Ask to be shown the card before allowing the installation work to commence and make a note of the installer QCC number Upon completion of the installation the installer is require...

Page 3: ... the unit is closer to the wall then the wall must be fire proof 3 The unit must be installed in a well ventilated area 4 Remove the plastic material protecting the stainless steel panels 5 Position the unit Check with a spirit level and bring to correct level using the floor adjusters on the legs 6 A gas cock must be incorporated in the supply pipe and fitted close to the unit A gas regulator gov...

Page 4: ... if pilot fails to light 4 When the control knob is turned to the first setting HIGH the burner will be ignitted by the pilot burner See drawing to see which knob operates which burner 5 For the second setting LOW depress and turn knob in a anti clockwise until it slots into position 6 To shut down the burners turn the controls clock wise until is locks in position pilot will still stay lit 7 When...

Page 5: ...e M4 pin 1 2 3114 17 Ignitor wire 1 3 3114 23 Ignitor for minisit 1 4 3114 24 Minisit valve 100 340 1 5 3114 26 Minisit black knob 1 6 dn 5969 Oven door 1 7 dn 5969 7 Oven door hinge plates 2 8 3114 19 Thermocouple 600mm long for top burners 6 9 3114 14 Thermocouple 900mm long for oven 1 10 3135 19 Gas cock knob 6 11 3115 18 Gas cock 3 8 6 12 3109 18 Pilot burner 3 way 1 13 3848 02 door counter we...

Page 6: ...Open the main gas control valve 5 Mix up a solution of soap and water to a 50 50 ratio Figure 1 To Reach Air Adjustments on Top Burners 1 2 3 CONTROLS AND SPARE PARTS FOR RG 6 GAS OPEN BURNER RANGE 6 Methodically brush the solution onto all the gas system joints including all the valve connections hose pipeconnections and regulator connections 7 The formation of bubbles indicates a gas leak 8 Turn...

Page 7: ...st iron grate and spider and observe the flame it should be a soft blue flame showing no yellow if the flame is harsh or has yellow tips correct this by adjusting the air intake of the burner To reach the air adjustments open the access panel above the oven a 6mm Hex locking screw should be unscrewed slightly and the adjusting sleeve moved to the optimum position then the screw tightened again DO ...

Reviews: