VULCAN GAS RANGES RG-6 OPEN BURNER

VULCAN CATERING EQUIPMENT (PTY)LTD

[  5  ]

REV5-03-2012  /  VFM06

Open Top – 6 x 27,000kJ / H x 130 diameter

VULCAN CATERING EQUIPMENT (PTY)LTD

PARTS ORDERING / SERVICE INFORMATION:

Parts / spares orders must be placed directly with your local branch / distributor. To help 

speed up your order, we require the following information:
1)  Model / Serial number

2)  Type of gas (L.P. or natural)

3)  Item Part number

4)  Quantity Required

The serial number data plate is sited on the front bottom right hand corner of the unit.
Service information may be obtained by calling your local branch / distributor.
When calling, please have the following information available:
1)  Model / Serial number

2)  Type of gas (L.P. or natural)

3)  nature of Service Problem

PRIOR TO THE INSTALLATION OF EQUIPMENT:

•  Read  the  operating  manual  to  make  sure  that  the  installation  meets  all  the 

requirements as specified within the Operating and Installation manual provided with 

your unit.

CLEANING PROCESS:

Please note

•  Always turn off the gas at the main gas supply, during maintenance and cleaning.
•  Clean the unit while it is still warm, it is easier to remove dirt.
•  When burners require cleaning, remove the cast iron grate and spider.
•  Use only warm soapy water and a soft cloth when cleaning the burners. The burners 

should be dry and obstruction free when replacing it.

•  Never use steel wool, soda or any other harsh abrasives for cleaning.
•  Do not hose the unit down.

TROUBLE SHOOTING:

COMPLAINT

POSSIBLE CAUSE

REMEDY

•  Unit not igniting

•  Main gas valve off

•  Switch on main gas valve

INSTALLATION:

1.   Before leaving the factory, the unit has been fully assembled and undergone final 

tests.

2.   Unit must be installed on a fire proof floor. If floor is made of wood, arrangement 

must be made to comply with local fire department regulations. Rear of unit must be 

at least 100mm from the wall. If the unit is closer to the wall then the wall must be 

fire proof.

3.   The unit must be installed in a well ventilated area.
4.   Remove the plastic material protecting the stainless steel panels.

5.   Position the unit. Check with a spirit level and bring to correct level using the floor 

adjusters on the legs.

6.   A gas cock must be incorporated in the supply pipe and fitted close to the unit. A gas 

regulator / governor set at the correct pressure must also be fitted close to the unit.

7.   This appliance to be operated with a 2.75kPa (for LP gas) and 2.0kPa (for natural 

Gas)  regulator  complying  with  the  regulations  of  the  SanS  1539:2008  with  a 

minimum capacity of 1900g/h -regulator not supplied.

8.   Before connecting the gas supply, check the serial plate and ensure that the unit 

is suitable for the type of gas being used. after connecting the gas supply, check 

carefully for leaks. as there may be air in the system, it will take several minutes to 

evacuate after turning the control on to light the pilots.

9.   For access to gas controls, remove the screws fixing the control panels to the side 

panels.

10.  The installation of appliance may only be carried out by a registered installer and 

that such installations shall comply with the requirements of SanS 1539:2008.

11.  Check that the correct jets are fitted to suit type of gas and altitude.
12.  Air intake adjustment slide burner must be set to give clear blue flame. Red and 

yellow is incorrect.

13. The unit is not intended for use by persons (including children) with reduced physical, 

sensory  or  mental  capabilities,  or  lack  of  experience  and  knowledge  unless  they 

have  been  given  supervision  or  instruction  concerning  use  of  the  appliance  by  a 

person responsible for their safety.

14. children should be supervised to ensure that they do not play with the appliance.

PLEASE NOTE

15.  The  installation  of  the  equipment  must  be  done  by  a  qualified  registered 

Technician all in compliance with statutory Health and Safety Regulations.

degree 1

2

3

4

5

6

7

8

 °c

100

134.3

168.6

202.9

297.2

271.5

305.8

340

 HEAT SETTINGS:

Summary of Contents for RG-6

Page 1: ...an catering Equipment Branches and dealers 3 Parts Ordering Service Information 4 Prior to Installation of Equipment 4 Heat Settings 4 cleaning Process 4 Trouble Shooting 5 Installation 5 Operation 6 Line drawing 8 Spares 9 Preventative Maintenance 10 Safety 12 VULCAN GAS RANGES RG 6 OPEN BURNER ...

Page 2: ...quipment Dealer for replacement Important Information For The User This appliance may only be installed by a registered LP Gas installer All registered installers are issued with a card carrying their registration number Ask to be shown the card before allowing the installation work to commence and make a note of the installer QCC number Upon completion of the installation the installer is require...

Page 3: ... the unit is closer to the wall then the wall must be fire proof 3 The unit must be installed in a well ventilated area 4 Remove the plastic material protecting the stainless steel panels 5 Position the unit Check with a spirit level and bring to correct level using the floor adjusters on the legs 6 A gas cock must be incorporated in the supply pipe and fitted close to the unit A gas regulator gov...

Page 4: ... if pilot fails to light 4 When the control knob is turned to the first setting HIGH the burner will be ignitted by the pilot burner See drawing to see which knob operates which burner 5 For the second setting LOW depress and turn knob in a anti clockwise until it slots into position 6 To shut down the burners turn the controls clock wise until is locks in position pilot will still stay lit 7 When...

Page 5: ...e M4 pin 1 2 3114 17 Ignitor wire 1 3 3114 23 Ignitor for minisit 1 4 3114 24 Minisit valve 100 340 1 5 3114 26 Minisit black knob 1 6 dn 5969 Oven door 1 7 dn 5969 7 Oven door hinge plates 2 8 3114 19 Thermocouple 600mm long for top burners 6 9 3114 14 Thermocouple 900mm long for oven 1 10 3135 19 Gas cock knob 6 11 3115 18 Gas cock 3 8 6 12 3109 18 Pilot burner 3 way 1 13 3848 02 door counter we...

Page 6: ...Open the main gas control valve 5 Mix up a solution of soap and water to a 50 50 ratio Figure 1 To Reach Air Adjustments on Top Burners 1 2 3 CONTROLS AND SPARE PARTS FOR RG 6 GAS OPEN BURNER RANGE 6 Methodically brush the solution onto all the gas system joints including all the valve connections hose pipeconnections and regulator connections 7 The formation of bubbles indicates a gas leak 8 Turn...

Page 7: ...st iron grate and spider and observe the flame it should be a soft blue flame showing no yellow if the flame is harsh or has yellow tips correct this by adjusting the air intake of the burner To reach the air adjustments open the access panel above the oven a 6mm Hex locking screw should be unscrewed slightly and the adjusting sleeve moved to the optimum position then the screw tightened again DO ...

Reviews: