Page 18
For technical questions, please call 1-888-380-0318.
Item 63618
S
AFET
y
M
AINTENAN
c
E
B
ASI
c W
EL
d
IN
g
W
EL
d
IN
g T
Ip
S
SETUP
Stick Welding
TO pREVENT SERIOUS INJURy ANd dEATH:
do not weld without grounding clamp.
When the operator is not holding the Electrode Holder, it must be
sitting on a nonconductive, nonflammable surface.
1. Turn the Power Switch to the OFF position, then
plug the Welder into a properly grounded, GFCI
protected, 120 VAC (20 amp rated) outlet or 240V
outlet.
The circuit must be equipped with delayed
action-type circuit breaker or fuses.
2. Set Electrode Holder down on
nonconductive, nonflammable surface
away from any grounded objects.
3. Turn the Power Switch ON.
WARNINg!
When Stick is selected, Welder
is energized, Hot Start is activated and
Open circuit Voltage is present.
4.
Select process:
Press Process Select
Button until
STIcK
process lights up.
process
Select
Button
120V
Amperage
Settings
(white)
240V
Amperage
Settings
(orange)
5. Set Amperage according to Stick Settings Chart.
NOTE:
Settings are approximate. Adjust as necessary.
IMpORTANT:
If Welder is plugged into 120V outlet, set
amperage according to settings on white band.
If Welder is plugged into 240V outlet, set amperage
according to settings on orange band.
Stick Settings chart
Electrode
Type
Electrode
diameter
Amperage
Range
6010 dc
6011 Ac/dc
3/32"
40-70
1/8"
75-130
5/32"
90-175
3/16"
140-225
6013 Ac/dc
1/16"
25-40
3/32"
40-90
1/8"
75-125
5/32"
105-175
7014 AC/DC
3/32"
75-110
1/8"
105-160
5/32"
150-200
7018 Ac/dc
3/32"
70-110
1/8"
90-160
5/32"
130-210
7024 AC/DC
3/32"
100-145
1/8"
110-175