TESTING PROCEDURE

WARNING

:

   

THE STEAMER AND ITS PARTS ARE HOT.  USE CARE WHEN OPERATING,

CLEANING OR SERVICING THE STEAMER.  THE COOKING COMPARTMENT CONTAINS LIVE
STEAM.  STAY CLEAR WHILE OPENING THE DOOR.

Once the steamer is installed and all mechanical connections have been made, thoroughly test the
steamer before operation.

1. Check that proper water, drain, and electrical connections have been made.

2. Open water valve.  Turn main power switch ON.  After approximately 15 minutes, the READY light

should come on, indicating that the water temperature is 205

°

F.

3. When the READY light comes on, turn the dial timer to 5 minutes.  With door open, observe that

no steam is entering the compartment and the COOKING light is not lit.

4. Close compartment door.  The COOKING light is lit and steam should be heard entering the

compartment.

5. Check drain line to ensure that water from the cold water condenser is flowing through the drain

line.

6. Open compartment door and observe that steam supply to the chamber is cut off.  The READY light

should come on; the COOKING light goes off.

7. Close compartment door and let cooking cycle finish.  When timer returns to 

0

, a buzzer will sound

signalling the end of the cooking cycle.  To silence the buzzer, turn the dial timer to OFF.

8. To turn the steamer off, turn the main power switch OFF — the steam generator will drain.  Leave

the door open to allow the inside to dry out.

Summary of Contents for COUNTER CONVECTION STEAMERS 52396

Page 1: ...PANY P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 FORM 30896 10 94 INSTALLATION OPERATION MANUAL FOR ELECTRIC COUNTER CONVECTION STEAMERS MODELS VSX3 VSX4 VSX5 ML S 52396 52397 52398 52399 MO...

Page 2: ...erify that the electrical service agrees with the specifications on the machine data plate which is located on the left side panel LOCATION Allow space for plumbing and electrical connections Minimum...

Page 3: ...TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT The wiring diagram is located on the right side panel as you face the steamer ELECTRICAL DATA Total KW Volts Hz Ph Kilowatts...

Page 4: ...t should be consulted before installing any steam generating equipment Untreated water contains scale producing minerals which can precipitate onto the surfaces in the boiler Due to the temperatures i...

Page 5: ...ial timer to 5 minutes With door open observe that no steam is entering the compartment and the COOKING light is not lit 4 Close compartment door The COOKING light is lit and steam should be heard ent...

Page 6: ...s have accumulated in the steam generator and that a DELIME procedure should be performed at the next convenient opportunity See Maintenance page 12 PREHEAT Turn the main power switch ON When the READ...

Page 7: ...erve their juice or retain broth Canned foods can be heated in their opened cans cans placed in 12 x 20 solid pans or the contents may be poured into solid pans DO NOT place unopened cans in the steam...

Page 8: ...inse with warm clear water and wipe with a dry cloth CAUTION Do not allow the door gasket to come in contact with food oils petroleum solvents or lubricants Keep the cooking compartment drain working...

Page 9: ...esh pre blanched or frozen and degree of doneness desired COOK IN SOLID PANS PRODUCT TIME minutes WEIGHT PER PAN Eggs Scrambled 10 12 8 Doz Rice Long Grain 25 2 Lb Cover with 4 cups water per pound Pa...

Page 10: ...Lb Scallops Fresh 4 3 Lb Scrod Fillets Fresh 3 5 4 Lb Eggs Hard Cooked 15 4 Doz Soft Cooked 9 10 4 Doz Soft Yoke for Caesar Salad 6 8 4 Doz Chicken Breasts Legs Thighs 20 15 Lb Turkey Frozen Breasts...

Page 11: ...Fresh 7 8 5 Lb Celery 1 Diagonal Cut 7 5 Lb Corn Yellow Whole Kernal Frozen 5 5 Lb Cobbettes Frozen 8 27 Ears 16 18 80 Ears Corn On Cob Fresh 10 12 18 Ears 16 18 54 Ears Peas Green 6 5 Lb Potatoes Wh...

Page 12: ...e the steam generator COLD WATER CONDENSER The steamer is equipped with a cold water condenser in the rear of the cooking chamber which helps to condense the steam prior to discharge into the drain Th...

Reviews: