background image

IMPORTANT FOR YOUR SAFETY 

 
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO 
INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD 
START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS 
MANUAL. 
 
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN 
THE EVENT THE SMELL OF GAS IS DETECTED.  THIS INFORMATION CAN BE 
OBTAINED FROM THE LOCAL GAS SUPPLIER. 
 
 
 

IMPORTANT

 

IN THE EVENT A GAS ODOR IS DETECTED, SHUT 
DOWN UNITS AT MAIN SHUTOFF VALVE AND 
CONTACT THE LOCAL GAS COMPANY OR GAS 
SUPPLIER FOR SERVICE. 
 
 
 

FOR YOUR SAFETY

 

DO NOT STORE OR USE GASOLINE OR OTHER 
FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF 
THIS OR ANY OTHER APPLIANCE. 
 
 
 
 
WARNING:  IMPROPER INSTALLATION, ADJUSTMENT, 
ALTERATION, SERVICE OR MAINTENANCE CAN 
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. 

 

READ THE INSTALLATION, OPERATING AND 
MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE 
INSTALLING OR SERVICING THIS EQUIPMENT. 

 
 
 

IN THE EVENT OF A POWER FAILURE, DO NOT 
ATTEMPT TO OPERATE THIS DEVICE. 
 

 

 

 

- 2 - 

Summary of Contents for CMJ24 ML-135124

Page 1: ...VCM48 ML 135127 VCM60 ML 135128 VCM72 ML 135129 www vulcanhart com MODELS MLS CMJ24 ML 135124 CMJ34 ML 135123 CMJ36 ML 135126 CMJ48 ML 135127 CMJ60 ML 135128 CMJ72 ML 135129 www wolfrange com ITW Food...

Page 2: ...TANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMM...

Page 3: ...located underneath the grease drip pan If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer immediately UNPACKING Immediately after unpacking...

Page 4: ...ards Committee Z223 400 N Capital St NW Washington DC 20001 or the Secretary Standards Council NFPA 1 Batterymarch Park Quincy MA 02169 7471 3 NFPA Standard 96 Vapor Removal from Cooking Equipment lat...

Page 5: ...supply connections and any pipe joint compound must be resistant to the action of propane gases Location of the gas inlet is at the top right rear corner of the top panel Codes require that a gas shut...

Page 6: ...ig 3 45 kPa or 14 W C TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds psig 3 45 kPa the Cheesemelter and its individual shutoff valve must be disconnected from the gas supply piping sys...

Page 7: ...TIONS 1 Turn gas shutoff valve and burner valve to the OFF position and wait 5 minutes 2 Turn gas shutoff valve ON Light the pilot adjacent to the main burner Adjust the pilot valve screw until the pi...

Page 8: ...ild soap and water applied with a damp cloth Rinse the surface with clean water and dry with a soft clean cloth Do not use abrasive cleaners or strong liquid cleaners on stainless steel surfaces as th...

Page 9: ...side 1 Cheesemelter not level side to side 2 Cheesemelter burner improperly installed Uneven heat front to back Cheesemelter not level front to back Dried out products 1 Melting time too long or produ...