TEMPERATURE PROBE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Parts may be hot. Use care when
handling them.
1.
Raise heating elements.
2.
3.
Disconnect temperature probe lead wires.
4.
Remove clamps / temperature probe (Fig. 18)
from heating element.
Fig. 18
5.
Remove clamps from temperaure probe.
6.
Remove temperature probe from element head
assembly.
NOTE:
Ensure grommet remains in place when
inserting temperature probe into element head
assembly.
7.
Reverse procedure to install.
8.
Check TEMPERATURE CONTROL
CALIBRATION.
HIGH LIMIT TEMPERATURE
SWITCH
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Parts may be hot. Use care when
handling them.
1.
Raise heating elements.
Do not sharply bend and kink or clamp
down on capillary tube or damage may occur.
2.
Open clamps (2, Fig. 19) and remove loop
clamps (3) and capillary tube / bulb (1) from
heating element.
Fig. 19
3.
4.
Remove high limit switch (1, Fig. 20) from
mounting bracket.
CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS
F45657 (0517)
Page 10 of 25