Fig. 20
5.
Carefully open cardboard cover (2).
NOTE:
Document wire connections.
6.
Disconnect wires from high limit switch.
7.
Remove grommet from element head assembly.
8.
Remove bulb, capillary tube, and high limit switch
from element head assembly.
NOTE:
Slide grommet onto capillary tube then insert
grommet into hole in element head assembly.
NOTE:
Make sure all electrical wires are clear of high
limit switch.
9.
Reverse procedure to install.
TILT SWITCH
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
2.
Disconnect tilt switch lead wires.
3.
Remove tilt switch (Fig. 21) from element head
assembly.
Fig. 21
4.
Reverse procedure to install.
CONTACTOR
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
NOTE:
Document wire connections.
2.
Disconnect wires from contactor (Fig. 22).
Fig. 22
3.
Remove screws and contactor.
CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS
Page 11 of 25