GENERAL

INTRODUCTION

This manual is for the Vulcan and Wolf Electric
Salamander Broilers. Procedures in this manual will
apply to all models unless specified. Pictures and
illustrations will be of model 36ESB unless otherwise
noted.

All of the information, illustrations and specifications
contained in this manual are based on the latest
product information available at the time of printing.

INSTALLATION, OPERATION AND

CLEANING

For detailed installation, operation and cleaning
instructions, refer to Installation & Operation Manual
sent with each unit. The manual is also available
online at www.vulcanequipment.com.

NOTE: 

 Using accessory options, Salamander

broilers can be mounted to the wall, over a range or
placed onto an appropriate table top by using 4" legs.

GRID POSITION AND HEAT

CONTROL SETTING

For detailed information refer to OPERATING THE
BROILER and GRID ADJUSTMENT in the Installation
& Operation Manual.

MODELS

Vulcan

36ESB-208

36ESB-240

36ESB-480

SPECIFICATIONS

 

3 PHASE MACHINE INFORMATION

Model

Total KW

NOMINAL AMPS PER LINE WIRE

OHMS per

Element

208V

240V

480V

X

Y

Z

X

Y

Z

X

Y

Z

36ESB-208

4.5

11.0

18.9

11.0

19.2

36ESB-240

4.5

9.4

16.4

9.4

25.6

36ESB-480

4.5

4.9

8.4

4.9

102.4

NOTES:

1.

Values in the table are nominal. Tolerance is +5/-10%.

2.

Voltage values are @ 60Hz.

3.

Resistance values (ohms) are @ 77° F.

4.

2.25KW per element assembly (left or right).

 

1 PHASE MACHINE INFORMATION

Model

Total KW

NOMINAL AMPS PER LINE WIRE

OHMS per Element

208V

240V

36ESB-208

4.5

21.6

19.2

36ESB-240

4.5

18.8

25.6

NOTES:

1.

Values in the table are nominal. Tolerance is +5/-10%.

2.

Voltage values are @ 60Hz.

3.

Resistance values (ohms) are @ 77° F.

4.

2.25KW per element assembly (left or right).

SALAMANDER ELECTRIC BROILER - GENERAL

Page 3 of 14

F45545 (0315)

Summary of Contents for 36ESB

Page 1: ...o perform the procedure Procedures for which you do not have the necessary tools instruments and skills should be performed by a trained Vulcan Service Technician The reproduction transfer sale or oth...

Page 2: ...NFINITE SWITCH 3 HEAT SWITCH 6 RACK SPRINGS 7 HEATING ELEMENTS 7 SERVICE PROCEDURES AND ADJUSTMENTS 9 INFINITE SWITCH TEST 208V 240V 9 3 HEAT SWITCH TEST 480V 9 RACK SPRING TENSION ADJUSTMENT 9 HEATIN...

Page 3: ...ID POSITION AND HEAT CONTROL SETTING For detailed information refer to OPERATING THE BROILER and GRID ADJUSTMENT in the Installation Operation Manual MODELS Vulcan 36ESB 208 36ESB 240 36ESB 480 SPECIF...

Page 4: ...um of NFPA 70E CAT III 600V UL CSA TUV listed Sensitivity of at least 20 000 ohms per volt Meter leads must also be rated at CAT III 600V Clamp on type amp meter for measuring heating element current...

Page 5: ...PANEL Disconnect the electrical power to the machine and follow lockout tagout procedures 1 Remove crumb tray 2 Remove FRONT PANEL 3 Position the rack assembly to access panel screws in the broiler o...

Page 6: ...nel screws in the broiler opening area Remove screws from this area and the front of panel Fig 5 6 Remove screws securing right side panel to broiler Slide panel toward the front of broiler until pane...

Page 7: ...prings 4 Access the bottom of broiler and remove springs from the lower arm casting and eye bolt Fig 9 5 Reverse procedure to install 6 Perform RACK SPRING TENSION ADJUSTMENT HEATING ELEMENTS Disconne...

Page 8: ...ack assembly and drip tray on each side to support the tray and remove from broiler Fig 12 6 From inside broiler cooking area remove screws securing heating element to broiler Fig 13 7 Note wire locat...

Page 9: ...percentage is not correct replace the switch as outlined under INFINITE SWITCH 3 HEAT SWITCH 3 HEAT SWITCH TEST 480V Disconnect the electrical power to the machine and follow lockout tagout procedures...

Page 10: ...NOTE Checking current draw is the preferred method over a resistance check when a clamp on type amp meter is available 1 If both measured values are approximately the same as listed in the machine in...

Page 11: ...des connections for supply voltage to the broiler SEQUENCE OF OPERATION NOTE On 208V 240V broilers the two heat controls are Infinite load switches On 480V broilers the two heat controls are 4 Positio...

Page 12: ...208 240V WIRING DIAGRAM Fig 16 SALAMANDER ELECTRIC BROILER ELECTRICAL OPERATION F45545 0315 Page 12 of 14...

Page 13: ...480V WIRING DIAGRAM Fig 17 SALAMANDER ELECTRIC BROILER ELECTRICAL OPERATION Page 13 of 14 F45545 0315...

Page 14: ...heat switches 480V are OFF or malfunctioning 3 Heating elements inoperative or malfunctioning Cooking problems product not done overdone 1 Refer to Installation Operation Manual for recommended grid...