SECTION 5 - TROUBLESHOOTING - 3-STAGE
5.6 DIAGNOSTIC TABLES
PERIPHERAL DRIVE CIRCUIT
Fault
Setup
Check
Results desired
All Y outputs
N/A
U6-1, 2, 6
high
No stuck bits
Turn furnace
Display/
No Error codes
Off then On
LED's
Display OK
Turn furnace
D2, D3, D4, D6
Not shorted or open
Off
MOTOR DRIVE CIRCUIT
Fault
Setup
Check
Results desired
No door up or down
Furnace in idle
U8-16
+12 VDC
when switch is activated
Disconnect J5
U8-10-15
Turn furnace on
Activate switch
Activate switch
Turn furnace off
Turn furnace on
U13-15
digital high
Motor switch
Other keys respond
At up or down
Add mA meter in
Stall
> 550 mA at up
position
series at J5
current
or down