background image

ABOUT YOUR WATER HEATER 

HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY? 

Installation requirements are 

shown on pages 

14 

to 

21. The water heater must be installed: 

 

by a qualified person, and 

 

in accordance with the installation instructions, and 

 

in  compliance  with  Standards  AS/NZS 3500.4,  AS 5601  or  AS/NZS 5601.1,  as  applicable  under  local 
regulations, and all local codes and regulatory authority requirements. 

 

 Warning:

 Temperature controllers 

must not

 be fitted to this water heater as part of a solar water heater 

system because water at a temperature much higher than the controller setting can be delivered. 
 
The pipe work between the solar storage tank and the in-series gas booster has a minimum recommended 
pipe  size  of  DN20, 

MUST BE

  of  copper  and  be  fully  insulated  in  accordance  with  the  requirements  of 

AS/NZS 3500.4. The insulation must be weatherproof and UV resistant  if exposed. The insulation must be 
fitted up to the connections on both the solar storage tank and the in-series gas booster. 
 

VICTORIAN CUSTOMERS 

Notice to Victorian Customers from the Victorian Plumbing Industry Commission. This water heater must be 
installed by a licensed person as required by the Victorian Building Act 1993. 
 
Only a licensed person  will give  you a Compliance Certificate, showing that the work complies with all the 
relevant  Standards.  Only  a  licensed  person  will  have  insurance  protecting  their  workmanship  for  6 years. 
Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate. 
 

DOES THE WATER CHEMISTRY AFFECT THE WATER HEATER? 

The  water  heater  is  suitable  for  most  public  water  supplies,  however  some  water  chemistries  may  have 
detrimental effects on the water heater, its components and fittings. Refer to 

“Water Supplies”

 on page 10. 

 
If you are in a known harsh water area or you are not sure of your water chemistry, have your water checked 
against the conditions 

described on page 

10. 

 

HOW LONG WILL THE WATER HEATER LAST? 

The  water  heater  is  supported  by  a  manufacturer‟s  warranty 

(refer  to  page 

31

)

.  There  are  a  number  of 

factors that will affect the length of service the water heater will provide. These include but are not limited to 
the  water  chemistry,  the  water  pressure,  the  water  temperature  (inlet  and  outlet)  and  the  water  usage 
pattern. Refer to 

“Precautions”

 on page 6. 

 

Summary of Contents for 244 027

Page 1: ...ter heater must be installed and serviced by a qualified person Please leave this guide with the householder Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 244 series 027...

Page 2: ...f Rheem Australia Pty Ltd Trademark of Rheem Australia Pty Ltd Note Every care has been taken to ensure accuracy in preparation of this publication No liability can be accepted for any consequences wh...

Page 3: ...er pages are intended for the installer but may be of interest About Your Water Heater 4 Water Supplies 10 Save A Service Call 11 Installation Water Heater 14 Connections Plumbing 22 Connections Elect...

Page 4: ...outlet temperature setting as the water passes through the water heater The heat produced by the burner is transferred to the water through the heat exchanger The water is heated to a constant temper...

Page 5: ...l outlet Take care not to touch the power plug with wet hands SAFETY This water heater is supplied with temperature sensors a FlameSafe protection system and a pressure relief valve These devices must...

Page 6: ...ion of the water heater and also damage components MINOR SIX MONTH MAINTENANCE It is recommended minor maintenance be performed every six months by the dwelling occupant The minor maintenance includes...

Page 7: ...at the solar heated water inlet and hot water outlet of the water heater if the water heater has been drained Open all of the hot taps in the house don t forget the shower Open the cold water isolati...

Page 8: ...risk of freezing then it is necessary to drain the water heater refer to Draining the Water Heater on page 8 Pipe work to and from the water heater must be adequately insulated to prevent freezing Th...

Page 9: ...from the Victorian Plumbing Industry Commission This water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a licensed person will give you a Complianc...

Page 10: ...mation should be sought from the supplier or it should be tested to ensure the water supply meets the requirements given in these guidelines for the Vulcan warranty to apply SATURATION INDEX The satur...

Page 11: ...appliance Has the gas line been purged of air after installation Refer to your plumber NO WATER FROM THE HOT TAP No flow of water from the hot tap may indicate a restriction in or failure of the cold...

Page 12: ...glass Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors If the collector glass becomes dirty hose down...

Page 13: ...e If an error code appears Close the hot tap and switch off the electrical supply to the water heater Check the gas isolation valve at the gas inlet to the water heater is fully open Wait 5 minutes th...

Page 14: ...uitable for installation as an in series gas booster to a solar water heater For information relating to the function and operation of the solar water heater refer to the Owner s Guide and Installatio...

Page 15: ...ured along the wall behind the water heater At least 300 mm between the top of the flue terminal and the eaves At least 500 mm between the flue terminal and the edge of any opening into the building s...

Page 16: ...g wind chill factor The solar preheat line to the water heater must be insulated with suitable thickness insulation if freezing conditions are likely to occur The insulation must be fitted to the unde...

Page 17: ...g valve to the solar storage tank but it MUST BE before the non return valve prior to an open circuit direct system The cold water line to the temperature limiting device can be branched off the cold...

Page 18: ...allation Two Temperature Zones Using a Temperature Limiting Device LEGEND In series Gas Booster as part of a Closed Circuit Indirect Solar Water Heater Installation Two Temperature Zones Using a Tempe...

Page 19: ...on of the return line connection on the water supply line to the water heater then either water will be supplied to the cold water inlet of the temperature limiting device at a temperature exceeding t...

Page 20: ...s Hourly Gas Consumption MJ Min Gas Pressure kPa Test Point Gas Pressure kPa Max Gas Pressure kPa minimum maximum Model 027 027 027 027 027 Natural 205 1 13 0 193 0 905 3 50 Propane 205 2 75 0 277 1 4...

Page 21: ...INSTALLATION WATER HEATER 21 TYPICAL INSTALLATION OUTDOOR LOCATION TYPICAL INSTALLATION ELECTRONIC CONTINUOUS FLOW GAS BOOSTER WATER HEATER FOR SOLAR PREHEAT WATER HEATER...

Page 22: ...efer also to Hot Water Delivery on page 17 and to Mains Water Supply on page 16 A disconnection union must always be provided at the cold water solar preheat inlet and hot water outlet on the water he...

Page 23: ...tions on both the solar storage tank and the in series gas booster A full flow isolation valve must be installed on the water line to the in series gas booster GAS INLET The gas connection is made at...

Page 24: ...red The water heater is supplied with a 1 8 metre lead and plug and requires a weatherproof 240 V 50 Hz general purpose outlet GPO to be located within 1 2 metres of the installation The GPO must be c...

Page 25: ...ated in the water heater is not adjustable To complete the installation it is necessary to check the gas supply pressure at the inlet to the water heater refer to Gas Inlet Pressure on page 25 the min...

Page 26: ...ensure the burners are fully ignited It may be necessary to open a second tap 8 Turn on all other gas burning appliances in the house which are on the same gas supply 9 Observe the gas pressure readi...

Page 27: ...et to the water heater 7 Open the gas isolation valve fully at the gas inlet to the water heater if not already open 8 Open a hot tap slowly until the burners ignite 9 Press and hold down the MIN butt...

Page 28: ...Code If an error code does appear on the LED display during the commissioning process it will be necessary to clear the error in order to complete the installation To clear an error code switch off th...

Page 29: ...n the LED display is the desired preset outlet temperature setting then proceed to step 7 as no further adjustment is necessary 6 Press the MAX button to increase or the MIN button to decrease the pre...

Page 30: ...eater Damage caused by freezing due to the unavailability of power at the water heater is not covered by the Vulcan warranty refer to Terms of the Vulcan Warranty on page 31 If the power has been swit...

Page 31: ...g or removing cupboards doors or walls and the cost of any special equipment to bring the water heater to floor or ground level or to a serviceable position is not covered by this warranty 2 5 This wa...

Page 32: ...rranty period 4 2 You are not entitled to make a claim under this warranty if your water heater a Does not have its original serial numbers or rating labels b Is not installed in Australia 5 HOW TO MA...

Reviews: