background image

R E I M A G I N E  

L O U D S P E A K E R S

WWW.VUEAUDIO.COM

MENU

EXIT

VUEDrive V6

al-8 array 3

MENU

EXIT

Configuration:

al-8 array 3

PRESET ASSIGNMENT, ACCESS AND CONTROL

FRONT PANEL PRESET ACCESS

Standard operation display

 showing the name of 

the amplifier on the top line, which can be changed in 
the System Vue software, and the current loaded preset 
on the second line.

Preset select display 

shown after the MENU 

button has been pressed.

The V3-i and the V242 do not have front panel displays or access to preset selection at the amplifier. For 
these two amplifier models you will need to access the amplifier through the SystemVue software.  The V4 
and V6 models can also be locked out of front panel access through the SystemVue software. 

The V4-d and V6-d have front panel displays and 
controls to access presets at the amplifier. 
In normal operation the front panel display will 
show the default name or the name assigned 
the amplifier in the SystemVue software, and the 
preset currently loaded.

Changing Preset at amplifier:
To change the currently loaded preset: 

1.  Press the MENU button and the display will 

change to show “Configuration:” on the top 
line. 

2.  Turn the control knob to run through the 

available presets in the amplifier’s memory. 

3.  When the desired preset is found stop and 

press exit and the preset will be loaded, and 
the display will return to the normal operation  
display.

Preset assignment, Access can be achieved through 

and one of the three network connectors.  The 
V-drive series is best run on a Dynamically assigned 
IP address, DHCP, managed Ethernet network.  The 
SystemVue software will automatically identify any 
Vue networked products on the network when it is 
launched.  For non-DHCP networks the VDrive System 
Engines will work and auto identify using the ad-hoc 
network conventions.  This may be slower or take 
some time to re-access if the amplifiers were already 
on a DHCP network.  Static addresses may also be 
used. Caution must be taken to manage the static 
IP addresses, so they are not repeated or place out 
of the users subnet mask range.  If placed out of the users Subnet mask range, SystemVue will still see the 
products, but it can not connect and communicate with them.  
The SystemVue software is available for download from vueaudio.com.  In the software you can, control the 
input volumes, select presets, adjust input EQ, manage all your network controlled Vue products and much 
more.

Summary of Contents for VUEDrive V242

Page 1: ...se during installation operation or maintenance The information provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Vue Audiotechnik website at www vueaudio com USER MANUAL V242 V3 V4 V6 NE T W ORK ED D S P A M P LI FI E RS ...

Page 2: ...from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with a cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer a...

Page 3: ......

Page 4: ...o not block vent openings and clean vent filter when visibly dirty 1 AC Power switch 2 Locking PowerCon connector 100 240VAC 50 60 Hz 3 Cooling fan rear exhausting air is pulled in the front of the amp do not to block the fan opening 4 Speaker output Single NL8 Speakon connector 5 Analog input and hard wired loop through XLR jacks 6 AES EBU digital input and buffered loop through XLR jacks V3 i RE...

Page 5: ...and B audio mute indicator V4 d FRONT PANEL FEATURES V4 d REAR PANEL FEATURES 8 Output channel A amplifiers 1 and 2 meters with input Clip output Limiter engaged indicator 6dB down from full output and Signal present indicator 9 Output channel A amp 1 and amp 2 Mute switches and indicators 10 Output channel B amp 1 and amp 2 meters with input Clip output Limiter engaged indicator 6dB down from ful...

Page 6: ...jacks 7 AES EBU digital input and buffered loop through XLR jacks V6 d FRONT PANEL FEATURES 8 Output channel A amp 1 and amp 2 meters with input Clip output Limiter engaged indicator 6dB down from full output and Signal present 9 Output channel A amp 1 and amp 2 Mute switches and indicators 10 Output channel B amp 1 and amp 2 meters with input Clip output Limiter engaged indicator 6dB down from fu...

Page 7: ...inal block connectors V242 REAR PANEL FEATURES 1 Power on indicator 2 A and B Amplifier indicators for Protection and Temperature 3 Sleep indicator lights when the amplifiers is in power down sleep mode 4 Wink indicator for identifying the amplifier over the network 5 Front cooling vent Do not block vent openings and clean vent filter when visibly dirty 5 Analog input A and B on two 3 pin 5 08mm s...

Page 8: ... will change to show Configuration on the top line 2 Turn the control knob to run through the available presets in the amplifier s memory 3 When the desired preset is found stop and press exit and the preset will be loaded and the display will return to the normal operation display Preset assignment Access can be achieved through and one of the three network connectors The V drive series is best r...

Page 9: ...s 1x 275 550 watts rms 2x 830 1600 watts rms 2x 275 550 watts rms 2x 830 1600 watts rms 4x 275 550 watts rms Average Burst 8Ω 4Ω 4x 300 700 watts 2x 1 250 2500 watts 1x 400 800 watts 2x 1 250 2500 watts 2x 400 800 watts 2x 1 250 2500 watts 4x 400 800 watts Output Connectors 2x Phoenix touch proof IPC 1x NL8 Pin1 Amp Ch1 Pin2 Amp Ch2 Pin3 Amp Ch3 2x NL4 Pin1 Amp Ch1 Pin2 Amp Ch2 2x NL8 Pin1 Amp Ch1...

Page 10: ...ntal and or consequential damages This warranty gives you specific legal rights VUE s liability under this product warranty is limited to the repair or replacement of the product at our option and VUE shall have no liability for any loss of use interruption of business lost profits or goodwill or for any incidental or consequential damages of any kind arising from the purchase or use of VUE produc...