background image

R E I M A G I N E  

L O U D S P E A K E R S

WWW.VUEAUDIO.COM

1.  Front panel network port jack.
2.  Power LED indicator
3.  Protection, Temperature for  A and B amplifiers, 
4.  Sleep indicator for when the amplifiers is in power 

down sleep mode.

5.  Wink indicator for identifying the amplifier over the 

network.

6.  Input channel A and B meters with input Clip, input 

Limiter engaged indicator, -6dB down from full input, 
and Signal present.

7.  Input channels A and B audio mute indicator.

V6-d REAR PANEL FEATURES

1.  AC Power switch
2.  Locking PowerCon connector (100 - 240VAC, 50-60 Hz)
3.  Cooling fan (rear exhausting, air is pulled in the front of 

the amp) do not to block the fan opening.

4.  Speaker output A and B - two NL8 Speakon connectors
5.  Analog input A and hard wired loop through XLR jacks.
6.  Analog input B and hard wired loop through XLR jacks.
7.   AES / EBU digital input and buffered loop through XLR 

jacks.

V6-d FRONT PANEL FEATURES

8.  Output channel A amp 1 and amp 2 meters with input 

Clip, output Limiter engaged indicator, -6dB down from 
full output, and Signal present. 

9.  Output channel A amp 1 and amp 2 Mute switches and 

indicators

10. Output channel B amp 1 and amp 2 meters with input 

Clip, output Limiter engaged indicator, -6dB down from 
full output, and Signal present.  

11.  Output channel B amp 1 and amp 2 Mute switches and 

indicators

12. Front cooling vent - Do not block vent openings and 

clean vent filter when visibly dirty.

8.  Two Ethernet port jacks for control with SystemVue 

network software and audio input with Dante network 
audio. Either port can be used. These jacks are 
individual ports on an internal Ethernet switch, so they 
can be linked to the next VDrive amplifier in a rack.  

When using an external Ethernet switch one 
jack should be connected to the network 
switch. Connecting both ports to the same 
network will cause contintion on the network.

Summary of Contents for VUEDrive V242

Page 1: ...se during installation operation or maintenance The information provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Vue Audiotechnik website at www vueaudio com USER MANUAL V242 V3 V4 V6 NE T W ORK ED D S P A M P LI FI E RS ...

Page 2: ...from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with a cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer a...

Page 3: ......

Page 4: ...o not block vent openings and clean vent filter when visibly dirty 1 AC Power switch 2 Locking PowerCon connector 100 240VAC 50 60 Hz 3 Cooling fan rear exhausting air is pulled in the front of the amp do not to block the fan opening 4 Speaker output Single NL8 Speakon connector 5 Analog input and hard wired loop through XLR jacks 6 AES EBU digital input and buffered loop through XLR jacks V3 i RE...

Page 5: ...and B audio mute indicator V4 d FRONT PANEL FEATURES V4 d REAR PANEL FEATURES 8 Output channel A amplifiers 1 and 2 meters with input Clip output Limiter engaged indicator 6dB down from full output and Signal present indicator 9 Output channel A amp 1 and amp 2 Mute switches and indicators 10 Output channel B amp 1 and amp 2 meters with input Clip output Limiter engaged indicator 6dB down from ful...

Page 6: ...jacks 7 AES EBU digital input and buffered loop through XLR jacks V6 d FRONT PANEL FEATURES 8 Output channel A amp 1 and amp 2 meters with input Clip output Limiter engaged indicator 6dB down from full output and Signal present 9 Output channel A amp 1 and amp 2 Mute switches and indicators 10 Output channel B amp 1 and amp 2 meters with input Clip output Limiter engaged indicator 6dB down from fu...

Page 7: ...inal block connectors V242 REAR PANEL FEATURES 1 Power on indicator 2 A and B Amplifier indicators for Protection and Temperature 3 Sleep indicator lights when the amplifiers is in power down sleep mode 4 Wink indicator for identifying the amplifier over the network 5 Front cooling vent Do not block vent openings and clean vent filter when visibly dirty 5 Analog input A and B on two 3 pin 5 08mm s...

Page 8: ... will change to show Configuration on the top line 2 Turn the control knob to run through the available presets in the amplifier s memory 3 When the desired preset is found stop and press exit and the preset will be loaded and the display will return to the normal operation display Preset assignment Access can be achieved through and one of the three network connectors The V drive series is best r...

Page 9: ...s 1x 275 550 watts rms 2x 830 1600 watts rms 2x 275 550 watts rms 2x 830 1600 watts rms 4x 275 550 watts rms Average Burst 8Ω 4Ω 4x 300 700 watts 2x 1 250 2500 watts 1x 400 800 watts 2x 1 250 2500 watts 2x 400 800 watts 2x 1 250 2500 watts 4x 400 800 watts Output Connectors 2x Phoenix touch proof IPC 1x NL8 Pin1 Amp Ch1 Pin2 Amp Ch2 Pin3 Amp Ch3 2x NL4 Pin1 Amp Ch1 Pin2 Amp Ch2 2x NL8 Pin1 Amp Ch1...

Page 10: ...ntal and or consequential damages This warranty gives you specific legal rights VUE s liability under this product warranty is limited to the repair or replacement of the product at our option and VUE shall have no liability for any loss of use interruption of business lost profits or goodwill or for any incidental or consequential damages of any kind arising from the purchase or use of VUE produc...