background image

 

VS Security Products LTD

 

ZZ009161, ZZ009178

 

Page 9 of 13

 

 

 

 

7.2 Current Monitor Test Points

 

 

 

 

The following table contains typical current values to be measured at specific points in the equipment. The values given are in 

amperes  and  may  differ  slightly  from  those  actually  measured  due  to  component  tolerance  plus  effects  due  to  operating 

temperature.

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

NOTE: 

 The degaussing coils are powered as part of a tuned resonant circuit.  This allows quite high circulating currents to be 

generated  within  the  degaussing  coils,  with  minimal  current  consumption  from  the  mains  voltage  supply.    However,  this 

technique requires that the waveform of the supply voltage contains minimal harmonic distortion.  A distorted waveform will 

result in an increase in current consumption.

 

 

 

 

The typical current consumption figures provided in this manual are when powered from a supply with minimal distortion.  Any 

increase  in  current  consumption  due  to  a  distorted  waveform  will  have  minimal  effect  on  the  degausser  performance, 

however, excessive current consumption should be avoided for obvious reasons.  In the event  of unexplained high currents, 

please consult your supplier

.

 

 
 

SECTION 8: PARTS LIST

 

 

 

8.1 ZZ009161 Parts List

 

 

 

 

 

 

Model

 

Voltage / Frequency

 

Current monitor test points (refer to circuit diagram)

 

  

1

 

2

 

3

 

4

 

5

 

6

 

ZZ009161

 

110

-

115v 60Hz

 

13

 

8

 

70

 

39

 

29

 

0.19

 

ZZ009178

 

240

-

220v 50Hz

 

7

 

N/A

 

68

 

30

 

37

 

0.09

 

ZZ009161 (110

-

115v, 60Hz)

 

Designation

 

Part No.

 

Quantity

 

Description

 

  

CA100005

 

1

 

Cable gland 16mm

 

TB2

 

CG200001

 

1

 

Terminal Block

 

TB2

 

CG200002

 

1

 

End Cover

 

TB2

 

CG200003

 

1

 

Jump Bar

 

TB1

 

CM100023

 

1

 

Terminal Block

 

  

FM100033

 

1

 

Guard 120mm metal

 

M1

 

FM100042

 

1

 

Fan 120mm

 

  

HS100101

 

4

 

Feet

 

Ind 1

 

OI100031

 

1

 

Neon

 

SW1

 

OI100030

 

1

 

Neon

 

RL1

 

RS100010

 

1

 

Relay

 

  

SH100150

 

1

 

Relay Cover

 

SW3

 

SP100002

 

1

 

Temperature Sensor

 

SW2

 

SW100016

 

2

 

Thermal Switch

 

CB1

 

SW100017

 

1

 

Circuit Breaker 15A

 

SW1

 

SW100123

 

1

 

Red lens

 

SW1

 

SW100125

 

1

 

Switch Body

 

SW1

 

SW100126

 

1

 

Switch Contacts

 

IND1

 

SW100121

 

1

 

Yellow Lens

 

IND1

 

SW100124

 

1

 

Indicator Body

 

IND1

 

SW100127

 

1

 

Dummy Socket

 

TX1

 

TX100030

 

1

 

Auto Toroid Transformer

 

  

MP003065

 

1

 

Fan Plate

 

SW4

 

SW100070

 

1

 

Security Key Switch

 

Ind2

 

OI100017

 

1

 

Flashing Led

 

R1

 

RP200013

 

1

 

220 ohm Resistor

 

RL2

 

RS100076

 

1

 

Relay Base

 

RL2

 

RS100077

 

1

 

24v ac Relay

 

D2

 

SD100025

 

1

 

Rectifier Diode

 

TX1

 

TX100069

 

1

 

Transformer

 

C6

 

CC100025

 

1

 

100 

μ

f Capacitor

 

  

XX003064

 

1

 

V91 Top

 

Summary of Contents for V91 DLT

Page 1: ...ZZ009161 ZZ009178 Rev 12...

Page 2: ...ept at least 2 metres 6 Feet from the degausser IMPORTANT the power on off switch used on this equipment is not an isolating switch it is recommended that this equipment should be operated from a sepa...

Page 3: ...ION PAGE 1 Specification 4 2 Introduction to the V91 DLT LTO Tape Degausser 5 3 Installation 5 4 Operation 6 5 Indicators Features 7 6 Maintenance Service 7 7 Tables 8 8 Parts List 9 This document ref...

Page 4: ...OPERATING VOLTAGE 110 115v 60Hz ZZ009161 220 240v 50Hz ZZ009178 CURRENT 12 amps typical 110 115v 60Hz 7 amps typical 220 240v 50Hz CIRCUIT BREAKER 15A 60Hz 10A 50Hz SECURITY KEY SWITCH Standard MOUNTI...

Page 5: ...npack the degausser carefully by disassembling the packing case and inspect it for signs of physical damage If damage is apparent a claim should be filed with the carrier immediately Once you have exp...

Page 6: ...degaussing coil must only be energised and de energised by using the power switch 4 2 Erasure of DLT and LTO Backup Tapes Other Cassettes and Cartridges Following the procedure below will ensure tapes...

Page 7: ...oil is monitored for excessively high temperatures and should this condition occur its operation will be inhibited until the coil has cooled sufficiently 5 4 Cooling A thermostatically controlled cool...

Page 8: ...ft in place The wire connections are of the push on spade type and are easily transferred to the new switch A high temperature epoxy resin part no EA 200 001 should be used to secure the new switch 6...

Page 9: ...obvious reasons In the event of unexplained high currents please consult your supplier SECTION 8 PARTS LIST 8 1 ZZ009161 Parts List Model Voltage Frequency Current monitor test points refer to circui...

Page 10: ...00010 1 Relay SH100150 1 Relay Cover SW3 SP100002 1 Temperature Sensor SW2 SW100016 2 Thermal Switch CB1 SW100049 1 Circuit Breaker 10A SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126...

Page 11: ...VS Security Products LTD ZZ009161 ZZ009178 Page 11 of 13 8 3 Circuit Diagram ZZ009161...

Page 12: ...VS Security Products LTD ZZ009161 ZZ009178 Page 12 of 13 8 4 Circuit Diagram ZZ009178...

Page 13: ...VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES Unit 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot California GU12 4QP 95667 UK USA...

Reviews: