Ensure that the floor of the facility can withstand the weight of the compressor. Install the
compressor on a level surface that is able to bear its weight.
Adjust the horizontal axis of the compressor using a levelling instrument.
If the compressor is not anchored to the base on which it is installed, the tilt angle with
respect to the horizontal surface must
not exceed 3°.
If the compressor is anchored to the base on which it is installed, the tilt angle with respect
to the horizontal surface must not exceed
7°.
Install the compressor in a facility where precipitation cannot reach.
Choose a facility for installing the compressor with a minimum level of dust.
Install the compressor at least 1.5 m from walls.
If multiple compressors are installed, there should be a 1.5 m minimum distance between
each compressor.
There should be a 4 m safety distance from the area of the operated equipment connected
to the compressor.
The facility in which the compressor is installed must be fitted with a combined extract-and-
input ventilation system.
The facility where the compressor is installed should be provided
with air inflow equivalent to twice the
compressor’s
capacity.
The volume of extraction ventilation must not exceed 40% of the air inflow capacity of the
input ventilation in a facility where the compressor is installed and fitted with an extract-
and-input ventilation system. The compressor should not be installed in a facility where the
temperature may drop below +5°С. In order to extract hot
air flowing out the compressor, an
air duct may be used that is up to 3 m in length and with a cross section 20% larger than
that of the air-outflow orifice from the
compressor’s
radiator. If an air duct longer than 3 m
is used, additional duct fans should be used.
3.4
Connection to the compressed airline
Provide the throughput capacity of the compressed-air line in accordance with the perfor-
mance of the compressor.
In order to avoid damage associated with seal failure of the compressed-air line, the
compressor should be connected via a flexible hose. All components of the compressed-air
line must have a working pressure no less than the compressor’s nominal pressure. Use a
pressure vessel with a capacity corresponding to the compressor’s performance and the
compressed air consumer.
Summary of Contents for COMPRAG A1108
Page 41: ...7 800 777 83 75 www v p k ru A1108 Comprag GmbH...
Page 79: ...7 800 777 83 75 www v p k ru A1108 Comprag Comprag...
Page 81: ...7 800 777 83 75 www v p k ru A1108 1 1 1 1 2...
Page 82: ...7 800 777 83 75 www v p k ru A1108 1 2 3 Comprag 4 5 6 1 3 1 2...
Page 83: ...7 800 777 83 75 www v p k ru A1108 3 4 5 6 7 8 9 10 11 12...
Page 84: ...7 800 777 83 75 www v p k ru A1108 1 4 1 2 3 4 5 6 90 A 7 8...
Page 85: ...7 800 777 83 75 www v p k ru A1108 1 5 1 2 3 4 5 6 7 8 1 3 9...
Page 86: ...7 800 777 83 75 www v p k ru A1108 9 10 11 12 13 14 15 16 17 18 19 20...
Page 91: ...7 800 777 83 75 www v p k ru A1108 11 22...
Page 92: ...7 800 777 83 75 www v p k ru A1108 2 4 2 3 1 2 3 2 4 5 3 6 8 13 6 16 6 15 14 13 14...
Page 93: ...7 800 777 83 75 www v p k ru A1108 2 5 2 5 t Log 2 3 4 5 1 2 3 5 100...
Page 99: ...7 800 777 83 75 www v p k ru A1108 3 7 5 C 40 C 40 3 4...
Page 101: ...7 800 777 83 75 www v p k ru A1108 3 5 2 2 6 3 4 4 1 A5 5 A 22 t LOG...
Page 102: ...7 800 777 83 75 www v p k ru A1108 LEDs t Log 4 1...
Page 103: ...7 800 777 83 75 www v p k ru A1108 LED COMPRAG 5 C C01 bar C01 M1 A 0 0 B 0 0 C 0 0 h m h m...
Page 107: ...7 800 777 83 75 www v p k ru A1108 0500h 5 1 2000h 2000h 0500h 5 1 M1 0000h 0000h 4 2...
Page 108: ...7 800 777 83 75 www v p k ru A1108 99 C C01 00 C 0 C01 M1 104 8A C 112 C 8 4bar 105 C 0110h...
Page 109: ...7 800 777 83 75 www v p k ru A1108 0110h 0110h 0110h 4 3 4 4 10...
Page 110: ...7 800 777 83 75 www v p k ru A1108 5 5 1 TO 1 TO 2 TO 3 TO 2 500 2000 4000 6000 6000 2 3 2000...
Page 111: ...7 800 777 83 75 www v p k ru A1108 5 2 1 5 2...
Page 113: ...7 800 777 83 75 www v p k ru A1108 5 4 2 2 1 1 2 5 4 1 5 4 2 1...
Page 114: ...7 800 777 83 75 www v p k ru A1108 5 5 1 2 5 5 5 6 4 3 2 1 2 2 5 3 4 5 6...
Page 115: ...7 800 777 83 75 www v p k ru A1108 5 7 C 1 5 7 5 8 90 5 8...
Page 116: ...7 800 777 83 75 www v p k ru A1108 D x0 005 M 5 9 5 5 5 10 2 6 6 1 5 3 5 3 5 40...
Page 117: ...7 800 777 83 75 www v p k ru A1108 5 2 5 8 13 13 7 7 1 20 35 85 7 2...
Page 118: ...7 800 777 83 75 www v p k ru A1108...