background image

 

 

Analogue Signal Transmitter  AST 3 

  

Introduction  

AST 3 is a high performance transmitter, designed for industrial measuring 
by means of strain gauge transducers. The compact module is easily 
installed on a DIN rail or a flat surface.  
Two slightly different versions of the transmitter module are available:  
 

AST 3B, designed for operation together with a control unit.  

 

Instructions for installation and set-up are found on a diskette,  

 

delivered with the transmitter module.  

 

AST 3P, with display window and function keys for set-up and  

 

measuring operations.  

This instruction includes the basic installation and set-up, required for correct 
measuring with the instrument.  

Additional installation and set-up of more instrument functions, not covered by 
this description, can also be performed.  
For a complete instrument description, refer to publication 600 232:  

AST 3  Technical Manual  

 

This description deals with the following points:  

  Using the AST 3P panel for measuring.  

  Quick installation.  

  ‘Quick set-up’ for AST 3P.  

  Data sheet calibration.  

  Deadweight calibration in two points.  

  Installation of deltaCOM.  

 

This description does NOT deal with the following points:  

  Connection of relay output.  

  Complete set-up (password, filters etc.).  

  Adjustment of levels and relay functions.  

  Adjustment of the analogue output.  

  Setting of communication parameters.  

  Table calibration.  

 Troubleshooting. 

 

 Diagnostics. 

 

AST 3P

Transducer

24 V DC

AST 3B

Transducer

24 V DC

Control unit

(deltaCOM)

 

Figure 1.  Different versions need different installation for parameter set-up.  

Summary of Contents for BHL Nobel AST 3

Page 1: ......

Page 2: ......

Page 3: ...supply 2 Start up 2 View alternatives 3 Zero setting 4 Installation Mechanical installation 5 Electrical installation 5 Set up programme deltaCOM 6 Quick set up calibration General 7 Common parameter...

Page 4: ......

Page 5: ...nt Additional installation and set up of more instrument functions not covered by this description can also be performed For a complete instrument description refer to publication 600 232 AST 3 Techni...

Page 6: ...d for about five seconds Then AST 3P is automatically switched over in Operation mode If the instrument is set for operator start up the text Press ENTER to start AST is displayed until the key to the...

Page 7: ...tual analogue output signal Level settings This view displays the switching levels for the two supervising channels If these channels are not in use level 0 is displayed Input signal This view display...

Page 8: ...enu Quick set up is displayed Press ENTER 5 The first parameter name Language is displayed Press a number of times until Set zero is displayed The parameter value for Set zero is a live weight value 6...

Page 9: ...les with other frequencies or high power an even wider distance is preferable 4 wire connection should be used if the integrated transducer cable can be connected directly at AST 3 By 4 wire connectio...

Page 10: ...preferably to a ground terminal at the mounting rail Set up programme deltaCOM AST 3B must be connected to transducer s and power supply and also to a PC with Windows 95 98 2000 XP NT4 0 to make set...

Page 11: ...e most accurate calibration method where known weights are used to give well defined loads on the scale Before selection of calibration method the value of some common instrument parameters must be se...

Page 12: ...ess to step forwards to next alternative or press to step backwards to the previous alternative until the correct alternative is displayed Language alternatives Press ENTER for 2 seconds to accept the...

Page 13: ...i e the weight value that corresponds to full range at the analogue output Press to get the parameter Capacity displayed Capacity 500 00 kg Press ENTER to make editing possible Capacity 0500 00 kg A...

Page 14: ...d by a cursor at the parameter value Then one of the alternatives must be chosen and accepted Press to get the parameter Calibration type displayed Calibration type Data sheet The value points out whi...

Page 15: ...eet unit is Newton N and the measurement unit is kg If data sheet unit and measurement unit are equal the value should be 1 00000 Press to get the parameter Conv factor displayed Conv factor 9 80665 P...

Page 16: ...the rated output should be set to 0 00000 Press to get the parameter Rated output 1 displayed Rated output 1 2 03900 mV V Press if the parameter value should be edited and make the editing like in po...

Page 17: ...r values should be saved i e copied to a specific memory in the instrument Alternatively the new values can be cancelled and all parameters will resume the values they had before Quick set up was star...

Page 18: ...isplayed parameter value is the load on the scale that was set for the lower calibration point in the last calibration normally zero unloaded scale Press ENTER Value cal p 1 XXXX XXX kg Actual measure...

Page 19: ...n to make editing possible Value cal p 2 0500 00 kg The displayed parameter value is the value for calibration point 2 from the last calibration with leading sign and a cursor The parameter value can...

Page 20: ...Set zero displayed and check that the scale is unloaded Set zero XXXX XXX kg Press ENTER to set the parameter value to zero Set zero 0000 00 kg The value is set to zero with leading sign and a cursor...

Page 21: ...ck set up was started Press ENTER to get the sub menu displayed Save changes No Esc Yes Press if you do not wish to exit from the set up mode Press to answer Yes and save the new parameter values Pres...

Page 22: ...lue cal p 2 500 0 kg 2 03900 mV V 2 03900 mV V 2 03900 mV V Weight value 123 4 kg 001 R1 On R2 On Start up Reset Quick set up Quick set up Language Resolution Measurement unit Main menu English kg 0 1...

Page 23: ...rement unit kg Resolution 0 1 Capacity 500 0 Ana output type 4 20mA Calibration type Data sheet Conv factor 9 80665 Number of transd 3 Rated load 2000 0 Rated output 1 2 03900 Rated output 2 2 03900 R...

Page 24: ...Operating instructions Quick installation...

Page 25: ......

Page 26: ...Document no 35158 Article no 600 243 R11 Vishay Nobel AB 2011 05 11 Subject to changes without notice www blhnobel com...

Reviews: