Troubleshooting
5.7 Vibrator Trouble
START
In the Test mode, select ‘Function Test’
then select ‘Vibrator Mode’.
U405 Pin 19 voltage
Level is higher than
3V ?
Replace U405.
Check the Signal level at the
U402 Pin 3.
NO
YES
U402 Pin 3
voltage is 0V when Vibrator
operated
NO
YES
Check CN301 Pin 26.
If CN301 Pin 26 is well connected then
replace Vibrator.
Replace U402.
END