Delivery Scope: 

 

 

 

Battery Protector 40  

 

Operating Manual 

 

 

Battery Life: 

 

Application of the Battery Protector 40 can prolong the battery life considerably. This is obtained by observation of the 
following general rules: 

 

In contrast to other battery types, batteries on lead basis 

do not have any

 harmful memory effect. Consequently: In case of 

doubt, partially discharged batteries are to be 

charged fully 

as soon as possible.  

 

Store only fully charged batteries 

and recharge them periodically, particularly in case of used (older) batteries and higher 

temperatures. Sulphation of the battery plates due to total discharge is to be prevented by immediate charging, particularly 
in case of low and high ambient temperatures.  
Observe the instructions and technical leaflets of the battery manufacturers. 
Keep batteries cool; choose an appropriate location for installation. 
  

Technical Data:

 

Battery 

Battery 

Battery 

Battery 

 

Protector  

Protector  

Protector  

Protector  

 

40 

40 Motor 

40/24 

40/24 Motor 

 

Nr. 3075 

Nr. 3073 

Nr. 6075 

Nr. 6073   

 

 

Nominal Operating Voltage (DC):  

12 V  

12 V  

24 V 

24 V

  

Operating Voltage Range DC:  

8.5 V - 25 V   

8.5 V - 25 V   

17 V - 36 V  

17 V - 36 V

 

Current Consumption ON 

2 mA;  0.002 A 

2 mA;  0.002 A 

2 mA;  0.002 A 

2 mA;  0.002 A

 

Current Consumption OFF 

2 mA;  0,002 A 

2 mA;  0,002 A 

2 mA;  0,002 A 

2 mA;  0,002 A

 

 

Current Consumption ON by Remote Control 

2 mA;  0.002 A 

2 mA;  0.002 A 

2 mA;  0.002 A 

2 mA;  0.002 A

 

Current Consumption OFF by Remote Control 

0 mA 

0 mA 

0 mA 

0 mA

 

 

Switching Current (Load) max.: 

 

 

40 A continuous, 52 A short-time 10 sec., 60 A 1 sec. 

 

Low-voltage Disconnection 

Disconnection Point:  

10.7 V  

11.8 V 

21.4 V 

23.6 V

 

Cutoff Delay:   

10 Sek.  

10 Sek.  

10 Sek.  

10 Sek

 

Cut-in Point (Automatic Return):  

12.5 V  

12.8 V 

25 V 

25.6 V

 

Cut-in Delay:   

2   Sec.  

2   Sec.  

2   Sec.  

2   Sec.

 

 

Overvoltage Disconnection 

Cutoff  Point:  

15.5 V  

15.5 V 

31 V 

31 V

 

Cutoff Delay:   

2  Sec.  

2  Sec.  

2  Sec.  

2  Sec.

 

Overvoltage Return:  

15.0 V  

15.0 V 

30 V 

30 V

 

Cut-in Delay:   

10 Sec.  

10 Sec.  

10 Sec.  

10 Sec.

 

 

Battery Types: 

Suitable for any lead storage battery with nominal voltage 12 V / 24 V 

  

 

Acid, Gel, Dryfit, Heavy Duty, Solar, Fleece, AGM etc. 

 

Fitting Position of Unit: 

any 

any 

any 

any 

Temperature Range Storage: 

-20/+50 °C 

-20/+50 °C 

-20/+50 °C 

-20/+50 °C

 

Protection Class: 

IP21  

IP21  

IP21 

 IP21

 

Dimensions (mm): 

90 x 60 x 38 mm 

90 x 60 x 38 mm 

90 x 60 x 38 mm 

90 x 60 x 38 mm

 

Weight: 

 

97 g 

97 g 

97 g 

97 g

 

Ambient Conditions, Humidity of Air: 

max. 95 % RH, No Condensation 

 

Declaration of Conformity: 

According to the stipulations of the regulations 2006/95/EG, 2004/108/EG, 95/54/EG this product corresponds to the 
following standards or standardized documents:  

 

EN55014;  EN55022 B;  DIN14685;  EN61000-4-2;  EN61000-4-3;  EN61000-4-4 

 

 

 

Disposal of the 
product in the 
normal household 
waste is not 
allowed.

 

The product 
conforms to RoHS. 

 

Thus, it complies 

with the directives for Reduction of 
Hazardous Substances in Electrical and 
Electronic Equipment.

 

 

 
 

 
 
 
 

 

 
 

Subject to misprints, errors and technical modification without notice. 

All rights reserved, particularly the right of reproduction. Copyright 

 VOTRONIC 01/2018.

 

Made in Germany by VOTRONIC Electronic-Systeme GmbH & Co. KG, Johann-Friedrich-Diehm-Str. 10, D-36341 Lauterbach 

Phone: +49 (0) 6641/91173-0    Fax: +49 (0) 6641/91173-20     E-mail: [email protected]     Internet: www.votronic.de 

 

Summary of Contents for Battery Protector 40

Page 1: ...for low battery voltage Display of the switching state being visible from outside Compensation of the voltage loss in the battery cable by separate sensor cable The electronic delay avoids premature reaction such as in case of voltage drop or if powerful consumers have been connected Suitable for continuous operation extremely low own consumption 0 002 A in conformity with EN13796 No own electrici...

Page 2: ...y after total discharge and battery recovery battery charging e g over 12 5 V e Automatically after overvoltage and decreasing voltage e g below 15 V f Manually by actuation of the change lever EMERGENCY If the battery voltage will again be decreasing due to consumer load the unit will be disconnected again This procedure should not be repeated unnecessarily often to maintain the longevity of the ...

Page 3: ...isk of gas or dust explosion exists Open air operation of the unit is not allowed Cables are always to be laid in such a way that damage is excluded Observe to fasten them tightly Never lay 12 V 24 V cables and 230 V mains supply cables into the same cable conduit empty conduit Live cables or leads being connected to the unit are periodically to be checked for insulation faults points of break or ...

Page 4: ... short time 10 sec 60 A 1 sec Low voltage Disconnection Disconnection Point 10 7 V 11 8 V 21 4 V 23 6 V Cutoff Delay 10 Sek 10 Sek 10 Sek 10 Sek Cut in Point Automatic Return 12 5 V 12 8 V 25 V 25 6 V Cut in Delay 2 Sec 2 Sec 2 Sec 2 Sec Overvoltage Disconnection Cutoff Point 15 5 V 15 5 V 31 V 31 V Cutoff Delay 2 Sec 2 Sec 2 Sec 2 Sec Overvoltage Return 15 0 V 15 0 V 30 V 30 V Cut in Delay 10 Sec...

Reviews: