background image

 

 

Tank Electrode 12-24 K

 

Tank Height 12 - 24 cm, 12 V and 24 V

 

Order-No. 5543 

Tank Electrode 15-50 K

 

Tank Height 15 - 50 cm, 12 V and 24 V

 

Order-No. 5545 

     According to Drinking Water Ordinance DIN 2001-2 

 

The tank transmitter had been designed for precise level measuring of fresh water tanks, sewage water tanks 

and feces tanks of plastic and metal material in campers, caravans and boats.  
Measurement of the level is effected fully-automatically without mechanically moving parts according to the 

capacitive method of measurement, and it is transferred to the display unit via a three-core cable.  
The electronic system is completely sealed. Thus, it is extremely robust and insensitive to soiling. 

 

Tank measuring sensor, suitable and required for VOTRONIC tank displays, 1 piece per tank: 

 

Tank Display Units:

 

Order No.  

12 V

 

Order No.  

24 V

 

 

Fresh Water Tank Display S

 

5311

 

5311 

 

Sewage Water Tank Display S

 

5313

 

5313 

 

Feces Tank Display S

 

5315

 

5315 

 

Info Panel Pro

 

5330

 

6330 

 

Votronic VBS 2 Bus System

 

All Types

 

All Types 

 

Votronic VPC System

 

All Types

 

All Types 

 

Previous Votronic tank displays since 1987

 

All Types

 

All Types 

 

 

For remote level measurement, the 

tank electrode

 

is installed directly at the tank. It is suitable for: 

 

 

Fresh water (if applicable, please observe the 

Guidelines for Drinking-Water Quality DIN 

2001-2) 

 

Sewage water, grey water 

 

Feces sewage water 

 
 

 

Plastic tanks, any material 

 

Metal tanks (aluminium, steel, stainless steel, 

etc.) 

 
 

 

Adjustable to tank heights: 
12

 

to 24 cm  or  15 cm to 50 cm. 

 

Functioning: 

The level in the tank is measured capacitively. The 

insulated stick (probe) and the surrounding water 

form a kind of "capacitor", the size of which is 

growing with the level, and which is measured by 

the electronic system. The contact to the water as 

"antipole" is effected by a stainless steel stick. 

 

 

Brief Instruction:

 

1.

 

Produce a mounting hole at the tank with a diameter of 38 mm or thread PG29. 

2.

 

Determine the kind of installation, inside or outside the tank, and measure the tank height. 

3.

 

Cut both measuring sticks to the desired length (observe a clearance of 10 - 20 mm between sticks and tank 

bottom). 

4.

 

Reinsert the insulating cap on the insulated stick (observe the tightness). 

5.

 

Install the tank transmitter inside or outside using the delivered packing ring. 

6.

 

Set the measured water depth at the scale. 

7.

 

Produce the electrical connection to the display unit. 

8.

 

Ready for start-up. 

 

Summary of Contents for 5543

Page 1: ...87 All Types All Types For remote level measurement the tank electrode is installed directly at the tank It is suitable for Fresh water if applicable please observe the Guidelines for Drinking Water Quality DIN 2001 2 Sewage water grey water Feces sewage water Plastic tanks any material Metal tanks aluminium steel stainless steel etc Adjustable to tank heights 12 to 24 cm or 15 cm to 50 cm Functio...

Page 2: ...nk electrode 12 24 K is for best results if possible the installation outside recommended Installation inside Installation outside After that the two stick probes must be cut to identical length metal saw strong side cutter bolt cutter It is important that a clearance of at least 10 20 mm is left between tank bottom and probe ends deposit up and down movement of the tank bottom and of the tank top...

Page 3: ... the tank electrode out of the full tank or bucket Fine adjustment of the set water depth can be corrected or changed at any time with full tank Final Installation The delivered packing washer is placed between tank and casing flange Screw the tank transmitter in place using the coupling ring In case of underfloor installation of the tank the adjuster must be protected with a permanently elastic s...

Page 4: ...ication in case of improper operation or external intervention We do not assume any liability for any damage resulting hereof The liability exclusion is extended to any service being executed by third which has not been ordered by us in writing Service is to be effected exclusively by VOTRONIC D 36341 Lauterbach Declaration of Conformity According to the stipulations of the regulations 2006 95 EG ...