- 4 -
Safety Regulations and Appropriate Application:
The tank measuring sensor has been designed according to the valid safety regulations.
Application is only allowed, if the unit is in technically faultless condition, with protected board battery
voltage of the indicated value and only for measurement of water or hydrous media.
•
Never use the unit at locations where the risk of gas or dust explosion exists!
•
The unit is to be disconnected from any connection prior to execution of electrically welding or work on
the electric system.
•
Cables are always to be laid in such a way that damage is excluded. Observe to fasten them tightly.
•
Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).
•
Check live cables or leads periodically for insulation faults, points of break or loosened connections.
Occurring defects must be remedied immediately.
•
If the user is not able to draw from the manual, which characteristic values are valid for a unit or which
regulations are to be observed, a specialist is to be consulted.
•
The user/buyer is obliged to observe any construction and safety regulations.
•
The unit is not equipped with parts, which can be replaced by the user.
•
The warranty period is 24 months from the purchase date (against presentation of the sales slip or
invoice).
•
The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the
technical specification, in case of improper operation or external intervention. We do not assume any
liability for any damage resulting hereof. The liability exclusion is extended to any service being executed
by third, which has not been ordered by us in writing. Service is to be effected exclusively by VOTRONIC
D-36341 Lauterbach.
Declaration of Conformity:
According to the stipulations of the regulations 2006/95/EG, 2004/108/EG, 95/54/EG this product
corresponds to the following standards or standardized documents:
EN55014; EN55022 B; DIN14685; DIN40839-1; EN61000-4-2; EN61000-4-3; EN 61000-4-4.
Disposal of
the product
in the
household waste
is not
allowed.
The product
conforms to RoHS.
Thus, it complies
with the directives for Reduction of
Hazardous Substances in Electrical and
Electronic Equipment
.
Technical Data:
Operating Voltage:
12 V-/24 V-DC Battery voltage (of the display)
Operating Voltage Range:
7...32 V
Current Consumption:
4...7 mA
Signal Output 0...100 %:
0...2.2 V,
Measuring Method:
capacitive, suitable for short-time and continuous operation
Tank Height, adjustable:
12…24 cm, 15…50 cm
Mounting Hole:
38 mm or thread PG 29
Flange Diameter:
46.5 mm
Length Connection Cable:
75 cm
Subject to misprints, errors and technical modification without notice.
All rights reserved, particularly the right of reproduction. Copyright
VOTRONIC 12/14.
Made in Germany by VOTRONIC Electronic-Systeme GmbH & Co. KG, Johann-Friedrich-Diehm-Str. 10, 36341 Lauterbach/GERMANY
Phone: +49 (0)6641/91173-0 Fax: +49 (0)6641 / 91173-20 E-mail: [email protected] Internet: www.votronic.de
Delivery Scope:
•
Tank Electrode 12-24 K or 15-50 K
•
Coupling Ring PG 29
•
Packing Washer
•
Mounting Instructions