background image

 

- 1 - 

 

Installation and Operating Manual 

 

Solar Data Extender 3n1 

No. 1440 

 
 

The Votronic Solar Data Extender aggregates the data of several solar controllers for representation on a single 
display.  

 

Please read the mounting instructions and the operating manual including the safety regulations 
completely prior to starting connection and start-up.

 

 

The Solar Data Extender is compatible with the following devices: 

 

VOTRONIC Solar Charging Controller in SR and MPP Technology (from serial No. 14Vxx.xxxxx) 

 

VOTRONIC Battery Charger, Type VBCS Triple

 

 

VOTRONIC LCD Solar Computer S (from serial No. 15V40.xxxxx) 

 

VOTRONIC VPC Series with Solar Function 

 

VOTRONIC Bluetooth Connector S-BC 

Functioning

 

The Solar Data Extender aggregates the data of up to three solar controllers for representation on a 
single display. The usual LCD displays (such as LCD Solar Computer S) can be used further.  
 
 

Installation and Connection: 

 

Later installation of the Solar Data Extender is possible at any time. 
It is equipped with three independent inputs (IN1, IN2, IN3). The signals are aggregated and they are 
are made available via the output (OUT), where a solar display (such as LCD Solar Computer S) can be 
connected.  

 
Installation  

The Solar Data Extender is connected between the Votronic Solar Charging Controller and the Solar 
Display  (such  as  LCD  Solar  Computer  S)  by  means  of  a  modular  cable,  which  is  included  in  the 
standard delivery. Connection IN1 must always be connected, since  it is used for voltage  supply to 
the unit. 
 

 

Summary of Contents for 1440

Page 1: ...NIC Bluetooth Connector S BC Functioning The Solar Data Extender aggregates the data of up to three solar controllers for representation on a single display The usual LCD displays such as LCD Solar Computer S can be used further Installation and Connection Later installation of the Solar Data Extender is possible at any time It is equipped with three independent inputs IN1 IN2 IN3 The signals are ...

Page 2: ...mportant For cascading IN1 must always be assigned to a solar controller Connection OUT can be also used to connect a VOTRONIC Bluetooth Connector S BC order No 1430 Operation During operation the unit recognizes automatically if units had been connected or removed Intervention of the user is not possible or necessary LED Flashing Pattern Simple and short flashing of the LEDs signalizes a connecte...

Page 3: ...fects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is responsible for the observation of construction and s...

Page 4: ...lable Accessories Extension Control Cable 5 m length Order No 2005 Declaration of Conformity In accordance with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 Disposal of the product in the household waste is not allowed The ...

Reviews: