Fault
Solution
Bearings noisy and/or turn difficult.
Replace bearings (1)
Fan does not start or rotates too slow.
No power supply:
• Turn on mains power supply
• Switch on controller
• Check fuse and replace, if necessary(1)
With power supply:
• Check condenser and replace, if necessary(1)
• Check motor and replace, if necessary(1)
Motor protection switch turns the fan off.
• Clean
• Replace bearings (1)
• Check motor and replace, if necessary (1)
• Repair or replace controller (1)
Impeller rotates slowly (less than 520 rpm
at full power supply)
• Check if all phases are connected
• Check if the correct voltage is supplied
(1) Use original spare parts only!
For best assistance please mention the article number (item 1 on the production label, see FIG I).
Vostermans Ventilation B.V.
Vostermans Ventilation Inc.
P.O. Box 3025
2439 S.Main St. – USA
NL-5902 RA Venlo – Holland
Bloomington, IL 61704
Tel. +31 (0)77 389 32 32 Tel. +1 309 827 - 9798
Fax +31 (0)77 382 08 93
Fax +1 309 829 - 1993
www.vostermans.com
www.vostermansusa.com
Vostermans Ventilation S.A.R.L. Vostermans Ventilation Sdn. Bhd.
B.P. 1801 330, Lot 2593, Jln Seruling 59, Kws3,
27018 Evreux Cedex Tmn Klang Jaya, 41200, Klang,
France Selangor D.E., Malaysia
Tel. +33 (0)2 32 38 11 00
Tel. +60 (0)33324 3638 (HL)
Fax +33 (0)2 32 33 37 12
Fax +60 (0)33324 1239
www.vostermans.com www.vostermans.com
Subject to alteration 03/2012
Vostermans Ventilation B.V. develops, manufactures and
distributes the full line of:
13. Complaints / questions
All rights reserved. Vostermans Companies is not responsible for inaccurate
or incomplete data. In case of questions and / or regards, please contact
12. Malfunctions / Repair
Caution: In case the fan does not rotate, this may be caused by the thermal protection. The fan
turns on again automatically. Contact your installer in case of malfunction.
To be checked by the installer:
• Is there a problem with the mains power supply?
• Is the fuse blown?
• Is the wiring loose?
• Have the bearings seized?
• Is the impeller blocked?
Summary of Contents for VF9427B
Page 1: ...FANS Specialist in Air VF9427B Casing Fan 92 Assembly manual...
Page 4: ...Fig II Tools 4 4 VF9427B 07 2016 Assembly manual 4 10 19 mm Pen 2 mm...
Page 12: ...24 8 6x 8 5 Nm 400 rpm 18 3x 10 6x 25 10 3x 5 3x 12 14 VF9427B 07 2016 Assembly manual 12...
Page 14: ...30 31 32 11 14 14 VF9427B 07 2016 Assembly manual 14...
Page 17: ...FANS Specialist in Air VF9427B Casing Fan 92 User Manual...