27
INSTRUCTION MANUAL POWER XXL – B 9000 – B 9000-S – B 12000 – B 12000-S
570500/12/2020/V2
below the power line at a 90° angle and as close as possible.
►
Do not power an electric animal fence with two separate electric fence energisers or from the
independent fence circuits of the same energiser.
►
Barbed wire or razor wire must not be electrified with an energiser.
►
Non-electrified barbed wire or razor wire may be used to support one or more offset electrified
wires of an electric animal fence. The electrified wires must be kept at a vertical distance of at
least 150 mm from the non-electrified wires by means of supports. Make sure that the non-
electrified wire is earthed at regular intervals.
►
There must be a minimum distance of 2.5 m between two separate electric animal fences, which
are powered by separate independently clocked electric fence energisers. If there should be a
physical barrier between the fences then only use electrically non-conductive materials or an
insulated metal barrier.
►
Ensure that all mains-operated auxiliary equipment connected to the electric animal fence has
the same degree of insulation as the energiser used.
►
Ensure that the auxiliary equipment is weatherproof. Outdoor use is only permitted if it has been
certified by the manufacturer and the equipment has a minimum degree of protection of IPX4.
2.3 SAFETY DURING OPERATION
WARNING AGAINST ELECTRICAL VOLTAGES
►
Lightning can cause fires and lead to malfunctions on electric fences. Separating the energiser
from the fence and power source before a storm or possible lightning strike can minimise the
effects of lightning. Redirect the current of the lightning strike to the ground before it damages
the energiser by installing a lightning rod between the fence and the energiser.
►
Avoid placing combustible objects near your electric fence. Cutting back shrubs in the vicinity
also reduces the risk of fire, as short circuits in the fence system can cause sparks.
►
Do not use an energiser if there is a risk of flooding the electric animal fence.
►
If the interval between pulses is less than 1 second, the energiser must be switched off
immediately and repaired, if necessary. If the pulse interval is more than 1.7 seconds, the fence
is no longer secure and the energiser must be checked.
DE
EN
FR
IT
NL
SV
ES
PL