background image

Important Safety Instructions

EN_1

1. Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions.

5. Do not use this apparatus near water. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturers 
instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.

13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.

14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases shall be placed on the apparatus.

15. 

WARNING:

 

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or

moisture.

16. Installation should be done only by qualified personnel and conform to all local codes.

20. 

CAUTION:

 

These servicing instructions are for use by qualified service personnel only. To

reduce the risk of electric shock do not perform any servicing other than that contained in the
operating instructions unless you are qualified to do so.

Website:www.voscom.com

Summary of Contents for VOS-8410FDDMR

Page 1: ...VOS 8410FDDT R series 8 Channel Video 4 Duplex Audio 1 Duplex Data Installation Manual Fiber Optic Transmission Systems VOSCOM TECHNOLOGIES CO LIMITED WWW VOSCOM COM TM...

Page 2: ...on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 13 Refer all servicing to qualified service personnel Servicing is required when the appar...

Page 3: ...istance is also limited by fiber bandwidth Power adapter is manufactured by third party and is supplied with fitted screw terminal output cables Power adapter included for standalone US European UK or...

Page 4: ...ED is green NOTE2 Avoid simultaneously connecting video signals to both the front BNC and rear BNC of the same channel Also since each video channel is factory terminated to 75 ohm unused BNCs should...

Page 5: ...k 1 2 3 4 5 6 7 8 Connect GND2 Forward PIN Connect Audio2 Forward Connect Audio2 Backward Connect GND2 Backward Connect Audio1 Backward Connect GND1 Backward Input 1 2 3 4 5 6 7 8 EXT1 Input Input Out...

Page 6: ...Block 1 2 3 4 5 6 7 8 Connect GND2 Backward PIN Connect Audio2 Backward Connect Audio2 Forward Connect GND2 Forward Connect Audio1 Forward Connect GND1 Forward Input 1 2 3 4 5 6 7 8 EXT1 Input Input O...

Page 7: ...pairs one is transmitter LED is red the other is receiver LED is green NOTE2 Avoid simultaneously connecting video signals to both the front BNC and rear BNC of the same channel Also since each video...

Page 8: ...simultaneously connecting video signals to both the front BNC and rear BNC of the same channel Also since each video channel is factory terminated to 75 ohm unused BNCs should not be used for loop th...

Page 9: ...e module the unit can be placed on a desktop or can be mounted to a wall NOTE Before mounting the VOS 8410FDDT transmitter VOS 8410FDDR receiver please ensure that there is adequate space at both ends...

Page 10: ...ER LED indicator that illuminates when power is applied to the rack unit 5 Fiber optic plug in modules video cards can be installed into any of the available 14 slots of the card cage Most modules req...

Page 11: ...ors and associated troubleshooting guidelines Table A Power Links Indicator Status Meaning Possible Cause Corrective Action Video LED VIDEO 1 VIDEO 2 Light Incoming video signal is present on thechann...

Page 12: ...t Data is not present on the channel No action required Data connection is faulty Check data connections Data communication cable is defective Replace cable The optical signal is not being received Re...

Page 13: ...repair replacements nonwarranty repairs advance replacements and credit returns To obtain an RMA Download from www voscom com and please complete the RMA as much detail as possible then send the RMA t...

Page 14: ...repair department will evaluate the returned product to determine whether it is a warranty or non warranty replacement and bill you accordingly We will invoice advance replacements at shipment and cre...

Page 15: ...ut notice 2 You can download the latest PDF document here www voscom com 3 Online Technical Support please E mail support voscom com 4 More detail product information please E mail sales voscom com or...

Page 16: ...R MOISTURE DO NOT LOOK INTO OPTICAL PORTS WITH POWER ON Headquarters Information Distributor Information VOSCOM TECHNOLOGIES CO LIMITED Hangzhou Zhejiang P R CHINA 310004 Tel 86 571 87389389 Fax 86 57...