25
Installation
N.B.
If the unit is equipped with a plug ignore the instructions describing the electrical connections.
• Use a single-phase alternating rated voltage supply, (Do not used with a power supply exceeding rated voltage ±10% ).
• Use a power cord which is between 2 mm
2
and 2.5 mm
2
thick, (Cords other than 2mm
2
- 2.5 mm
2
single-core cords cannot
be used).
(A drop in voltage is possible if the power cord exceeds
11m in length, so we recommend using a 2.5mm2
cord.).
Wire the unit
(Fig.19)
Embed the switch box in the installation location
(1 switchbox no cover)and wire the power cord
(with the green and yellow combined is ground line).
• If no switchbox is used, the power cord will be pushed out,
and prevent the unit from being installed firmly against the
wall.
Attach the installation panel to the wall using the 6
installation screws.
(Fig.20)
• If the wall is concrete, use commercially available metal
screw plugs(curl plugs, etc.)
• If the wall is not concrete, reinforce it before installation.
• Place the drilling stickers on the wall and drill the holes.
• Insert the wall plugs into the holes and fasten the
mounting plate as shown in the figure.
ENGLISH
19
20
Remove the drain tank and
the filter
(Fig.21)
• When installing with a plug,
continue from Fig. 25;
• For direct connection to the
electric line, continue from
Fig. 22;
Take the cover off the electric box and
take the cables (Fig. 22);
• unscrew the two screws of the cover;
open the cover;
• unscrew the two screws of the cable
gland and the 3 screws of the terminal
board; take the cables.
21
22