background image

Description and operation

Fig. 1÷4

The  appliance  you  have  purchased  has  been
specifically  designed  for  continuous  mechanical
extract ventilation of dwellings with between 2 and 7
rooms (from F2 to F7 types under French legislation). 
The  premium  quality  of  the  materials  and
components used as well as the advanced air design
of  the  aerodynamic  sections  ensure  that  ventilation
requirements are met. 
The appliance must generally be positioned in the loft
or  a  suitable  cupboard  and,  if  possible,  in  a  central
position in relation to the extract vents. 
It can be installed on a wall, floor or ceiling, using a
support  or  fixed  with  suspension  wires  to  the  4
anchor points (fig. 7). 
Air  extraction  and  circulation  with  this  appliance  is
quiet and uninterupted. 
Stale air is extracted via the fixed extract grille in the
non-habitable  "wet"  rooms  (kitchens,  utilities,
bath/shower rooms and WCs). 
A  minimum  10  mm.  gap  at  the  bottom  of  the  doors
allows the air to circulate correctly. 
In the kitchen, if necessary, it is possible to switch the
fan  onto  maximum  speed  to  extract  cooking  smells
and condensation. Afterwards, turn the control back
onto low speed continuous operation.

Warning

Ventilation  must  be  continuous.  Never  stop  the
ventilation unit, except of course for maintenance or
cleaning.

Distribution and elements of the appliances:

VORT PENTA

(fig. 1)

• 1 air outlet Ø 125, 
• 1 regulator for kitchen intake Ø 125,
• 2 regulators for bathroom intakes Ø 80 equipped

with fixed extract grille of 30 m

3

/h 

• 4 blanking plugs,
• 2 suspension wires,
• 1 support.
By purchasing the specific accessories it is possible,
according  to  need,  to  convert  the  appliance  into  a
configuration with up to 5 room regulators by adding
another 3 bathroom intakes Ø 80.

KIT VORT PENTA

(fig. 2)

(It is not available in the UK)
• 1 air outlet Ø 125,
• 1 regulator for kitchen intake 

Ø

125,

• 2 regulators for bathroom intakes 

Ø

80 equipped

with valves of 30 m

3

/h

• 2 regulators for bathroom intakes 

Ø

80 equipped

with valves of 15 m

3

/h

• 1 fixed extract grille 

Ø 

125,

• 2 fixed extract grilles 

Ø

80,

• 1 switch,
• 4 blanking plugs,
• 2 suspension wires,
• 1 support.
By  requesting  the  specific  accessory  it  is  possible,
according  to  need,  to  convert  the  appliance  into  a
configuration  with  up  to  5  bathroom  regulators  by

applying 1 bathroom intake 

Ø

80.

KIT VORT PENTA OEM CHANTIER

(fig. 3)

(It is not available in the UK)
• 1 air outlet Ø 125,
• 1 regulator for kitchen intake Ø 125,
• 2 regulators for bathroom intakes Ø 80 equipped

with valves of 30 m

3

/h

• 1 fixed extract grille Ø 125,
• 2 fixed extract grilles Ø 80,
• 3 blanking plugs,
• 2 suspension wires.
By requesting the specific accessory it is possible,
according to need, to convert the appliance into a
configuration with up to 5 bathroom regulators by
applying 1 bathroom intake Ø 80.

Valvles identification
Fig. 4.

Safety

•  Do  not  use  this  appliance  for  functions  other  than

those described in this booklet.

• After  removing  the  appliance  from  its  packaging,

ensure that it is complete and undamaged: 
If  in  doubt  contact  a  professionally  qualified
electrician or contact Vortice*. 
Do not leave packaging within the reach of children
or differently able persons.

• Certain fundamental rules must be observed when

using  any  electrical  appliance:  a)  Never  touch
appliances with wet or damp hands; b) Never touch
appliances while barefoot; c) Never allow children to
touch or play with the appliance;  d) The use of this
appliance  by  incapacitated  people  shold  be  under
supervision.

• Store the appliance out of the reach of children and

differently able persons after deciding to disconnect
it from the power supply and use it no more.

• Do  not  operate  the  appliance  in  the  presence  of

inflammable  vapours  (alcohol,  insecticides,  petrol,
etc.).

• Do not sit on or leave objects on the appliance.

• Do  not  make  modifications  of  any  kind  to  this

appliance.

• Do not expose this appliance to the weather (rain,

sun, etc.).

• Regularly inspect the appliance for visible defects. 

If any faults are found, do not operate the appliance;
contact Vortice immediately.

• If the appliance does not function correctly or

develops a fault, contact Vortice immediately.
Ensure that only genuine original Vortice spares
are used for any repairs.

7

ENGLISH

Warning:

this symbol indicates that care must
be taken to avoid injury to the user

!

Caution:

this symbol indicates that care must 
be taken to avoid damaging the appliance

!

Summary of Contents for VORT PENTA

Page 1: ...VORTICE LIMITED Beeches House Eastern Avenue Burton on Trent DE13 0BB Tel 44 1283 492949 Fax 44 1283 544121 UNITED KINGDOM VORTICE FRANCE 15 33 Rue Le Corbusier Europarc 94046 CRETEIL Cedex Tel 33 1...

Page 2: ...4 Sicurezza 4 Collegamento aeraulico 5 Applicazioni tipiche 5 Installazione 5 Collegamenti elettrici 5 Possibili altre connessioni 5 Manutenzione pulizia 5 Informazione importante per lo smaltimento a...

Page 3: ...17 A k rnyezetbar t megsemmis t s rdek ben fontos inform ci 18 nainte de a instala i de a conecta produsul citi i cu aten ie aceste instruc iuni Vortice nu va putea fi considerat responsabil pentru e...

Page 4: ...e di valvole da 15 m3 h 1 bocca di aspirazione 125 2 bocche di aspirazione 80 1 interruttore 4 tappi 2 cordicelle di sospensione 1 supporto di sostegno Richiedendo lo specifico accessorio possibile se...

Page 5: ...ore Lavare con acqua solo le prese di regolazione Non immergere l apparecchio in acqua o in altri liquidi Verificare che la sezione di ingresso delle prese d aria situate verso l esterno sia libera Il...

Page 6: ...nuova apparecchiatura equivalente L utente responsabile del conferimento dell apparecchio a fine vita alle appropriate strutture di raccolta pena le sanzioni previste dalla vigente legislazione sui ri...

Page 7: ...nsion wires 1 support By requesting the specific accessory it is possible according to need to convert the appliance into a configuration with up to 5 bathroom regulators by applying 1 bathroom intake...

Page 8: ...d to the electrical data on data plate A fig 5 Air connection The regulators for bathroom intakes 80 and the blanking plugs are fitted by pressing them onto the fan casing and they are interchangeable...

Page 9: ...domestic waste but must be taken to a collection centre for waste electrical and electronic equipment or returned to a retai ler on purchase of a replacement It is the user s responsibility to dispose...

Page 10: ...ec r gulateurs de 15 m3 h 1 bouche d extraction 125 2 bouches d extraction 80 1 commutateur 4 bouchons 2 cordelette 1 support de fixation En demandant l accessoire sp cifique il est possible selon les...

Page 11: ...ou m langes explosifs et inflammables L appareil ne peut tre utilis comme activateur de chauffe eau po le etc et il ne doit pas expulser dans les conduits d air chaud de ces appareils Ne pas couvrir...

Page 12: ...cycle de vie il devra tre trait s par ment des d chets domesti ques Il devra donc tre confi un centre de collecte s lective pour appareils lectriques et lectroniques ou rap port au revendeur lors de l...

Page 13: ...das de v lvulas de 15 m3 h 1 boca de aspiraci n 125 2 bocas de aspiraci n 80 1 interruptor 4 tapones 2 cuerdas de suspensi n 1 soporte de sost n Seg n las necesidades es posible pedir el accesorio esp...

Page 14: ...de regulaci n No sumergir el aparato en agua ni en otros l quidos Comprobar que la secci n de entrada de las tomas de aire al exterior est libre El flujo de aire o de humos que se ha de canalizar no d...

Page 15: ...durante la compra de un aparato equivalente El usuario deber llevar el aparato a un punto de recogida selectiva para su eliminaci n de lo contrario se aplicar n las sanciones previstas por las normas...

Page 16: ...0 15 m3 h os szeleppel 1 elsz v ny l s 125 2 elsz v ny l s 80 1 kapcsol 4 dug 2 felf ggeszt dr t 1 al t maszt s A sz ks ges tartoz kok megrendel s vel a saj t ig nyeknek megfelel en t lehet alak tani...

Page 17: ...berendez st ne mer tse v zbe vagy m s folyad kba Ellen rizze hogy a k lvil g fel kialak tott leveg bemeneti csatlakoz sok szabadok legyenek Az elt vol tand leveg vagy f st tiszta vagyis zs ros r szec...

Page 18: ...felhaszn l felel a hullad kokra vonatkoz rv nyes jogszab lyok ltal meghat rozott szankci k terhe mellett az rt hogy a berendez st a hasznos lettartam nak lej rta ut n a megfelel int zm nynek tadja A m...

Page 19: ...prijin Cer nd accesoriul specific e posibil n func ie de propriile necesit i s transforma i aparatul ntr o configura ie cu p n la 5 regulatoare sanitare aplic nd 1 priz sanitar 80 KIT VORT PENTA OEM C...

Page 20: ...latorului Sp la i cu ap numai prizele de reglare Nu introduce i aparatul n ap sau n alte lichide Verifica i ca sec iunea de intrare a prizelor de aer situate spre exterior s fie liber Fluxul de aer sa...

Page 21: ...il de predarea aparatului la terminarea duratei de via util c tre structurile corespunz toare de colectare sub pedeapsa sanc iunilor prev zute de legisla ia n vigoare privind de eurile Colectarea dife...

Page 22: ...F2 F7 4 7 VORT PENTA 1 1 125 1 125 2 80 30 3 4 2 1 5 3 80 VORT PENTA 2 1 125 1 125 2 80 30 3 2 80 15 3 1 125 2 80 1 4 2 1 5 1 80 KIT VORT PENTA OEM CHANTIER 3 1 125 1 125 2 80 30 3 1 125 2 80 3 2 5 1...

Page 23: ...Vortice b c d Vortice Vortice Vortice Vortice 3 a b c 5 80 15 3 30 3 4 80 125 1 5 125 23 O e...

Page 24: ...6 8 9 15 16 19 20 21 22 29 30 24...

Page 25: ...1 4 25 4...

Page 26: ...6 8 9 15 16 19 20 21 22 29 26 A 5 4 30...

Page 27: ...27 FIGURE FIGURES FIGURES FIGURAS BRA FIGURILE 1 VORT PENTA 2 KIT VORT PENTA 3 KIT VORT PENTA OEM CHANTIER...

Page 28: ...28 4 5 6...

Page 29: ...29 7 VORT PENTA KIT VORT PENTA KIT VORT PENTA OEM CHANTIER VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA 8...

Page 30: ...30 9 10 11 12 13 VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA...

Page 31: ...31 14 15 VORT PENTA KIT VORT PENTA VORT PENTA KIT VORT PENTA...

Page 32: ...32 16 M II I N L N1 L2 3 17 M II N N1 3 L2 I L 17A 18...

Page 33: ...33 19 3 L2 N1 L N 20 Commutazione multipla Multiple switching Conmutaci n m ltiple T bbsz r s tkapcsol s Comutare multipl...

Page 34: ...999 4 Interruttore cucina 5 Interruttore bagno 6 Lampada EN 1 3 positions terminal board 2 Relay 3 C Timer cod 12999 4 Kitchen switch 5 Bathroom switch 6 Lamp ES 1 Regleta de 3 posiciones 2 Relay 3 C...

Page 35: ...35 22 23 24...

Page 36: ...36 25 26 27 28...

Page 37: ...9 30 BNC BNO BC SC S1 S2 S3 L1 N1 L N L N B C Interruttore bipolare 2 poles switch C N1 L2 3 4 A A Morsettiera apparecchio Appliance terminal block B Morsettiera scatola comandi Control box terminal b...

Page 38: ...38 Note...

Page 39: ...39 Note...

Page 40: ...toutes les variations afin d am liorer ses produits en cours de commercialisation Vortice S p A se reserva el derecho de incorporar todas las mejoras necesarias a los productos en fase de venta Die Fi...

Reviews: