HIGH

 

Operation for fast humidification of larger rooms. High-speed operation 
will evaporate 3.5 gallons of water (+/- 10%) in 24 hours of continuous 
operation. (This assumes room conditions of 70º F and 30% relative 
humidity.) 

LOW 

Operation for quiet, nighttime use or smaller rooms. On Low operation, 
your humidifier may run without refilling for extended periods. 

HUMIDITY – 40%–60% OR CONTINUOUS

Set the humidity level by pressing the HUMIDITY button until the 
desired humidification level is illuminated. The humidifier will operate 
until the desired humidity level is reached. At this point, the mist will 
turn off but the fan will continue to run. The Humidity Level indicator 
light will remain on. If the mist does not turn on, the humidity setting 
may be lower than the room humidity level. Increase the humidity set 
point until the mist turns on. This is an indication of the level of humidity 
already in the room. While in Continuous setting, the humidifier will run 
continuously (both fan and mist).

HOW TO USE

1.

 

Position humidifier to not blow directly on objects or plants. Plug power 

cord into 110–120 volt AC outlet.

2.

 

To turn humidifier on, press Power Button. The LCD screen will 

illuminate when powered On and as settings are adjusted. Once 
settings have been selected the LCD screen will dim.

3.

 

Select Mist Condition, Fan Speed and desired Humidity Level (or 

Continuous) for a personalized experience. The humidifier also offers 
two programmed settings: 

• 

Auto1 - Continuous misting, cool mist, low fan speed.

• 

Auto2 - Continuous misting, warm mist, high fan speed.

The temperature of the mist on Warm Mist setting is approximately 94-98 
degrees at the Mist Outlet. However, the mist will feel cooler to the touch 
because it is immediately entrained in the Vortex beam of air generated by 
the fan.

Note:

 Lower humidity control settings or turn off humidifier if moisture 

forms on walls or windows.

4.

 

Notifications:

Refill Tank

 - Notifies you when the Water Tank needs to be refilled. 

Will automatically turn off after it has been refilled.

Clean Unit

 - Displays after 400 hours of operation. It is recommended 

to clean your Humidifier at this time (see CLEANING). To reset 
notification, press and hold the Power Button for 3 seconds.

Replace Mineral Cartridge

 - Displays after 800 hours of operation. It 

is recommended to replace the Mineral Cartridge at this time (see 
MINERAL CARTRIDGE). To reset notification, press and hold the 
Power Button for 3 seconds.

Summary of Contents for ULTRA1

Page 1: ...model ULTRA1 vornado com ULTRASONIC WHOLE ROOM HUMIDIFIER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...2 English vornado com 800 234 0604 help vornado com we expect this product to be PERFECT if it s not WE will make it right ...

Page 3: ...rtant Safety Instructions 4 Getting Started 7 Features 8 Controls 9 Filling Water Tank 10 How To Use 11 Mineral Cartridge 12 Automatic Refill Program 12 Cleaning 13 Storage 15 Troubleshooting 16 Warranty 17 CONTENTS ...

Page 4: ...nstable surface or near water The appliance power supply power cord and plug cannot come into contact with water Do not use this product on wet surfaces Do not use this product in a bathtub or shower or position product where it may fall into a bathtub laundry swimming pool or other water container Do not use this product outdoors or expose it to weather or elements Do not run cord under carpeting...

Page 5: ... electric shock Do not pour water through the top Outlet Air Grill on the power head Turn the humidifier off if the relative humidity exceeds 60 Humidity levels above 60 may allow moisture to build up indoors and condense on surfaces where microorganisms can settle and grow For accurate readings use a hygrometer which is available at most hardware stores and home centers The Mist Outlet must be us...

Page 6: ...terference to radio communications If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to contact Vornado Consumer Service Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the product ...

Page 7: ...h a humidistat may run constantly for a day or so and thus evaporate large quantities of moisture When the home and its furnishings have absorbed moisture and become stabilized at the desired humidity level the amount of water used will diminish and the humidifier operation will maintain the desired humidity level GETTING STARTED Check for Leaks Damage due to shipping may cause leaks in Base or Wa...

Page 8: ...ereby softening the water and reducing harmful mineral buildup on the Transducer WATER TANK Large 2 gallon capacity allows for fewer refills MIST OUTLET Moist air is dispersed through the Mist Outlet and projected into Vornado s signature Vortex beam of air circulating the moist air throughout the entire room BASE Durable and easy to clean CLEANING BRUSH Used for cleaning the Base in hard to reach...

Page 9: ...OFF Turn the humidifier On Off HUMIDITY Control humidity level at 40 60 allow unit to run continuously or select from Auto1 or Auto2 MIST CONDITION Select Cool or Warm Mist Output FAN SPEED Select desired HIGH or LOW fan speed on ...

Page 10: ...ndle and pulling toward you A 3 Turn Water Tank upside down and remove Cap B 4 Fill Water Tank with cool tap water C 5 Ensure Gasket rubber ring around Cap is properly positioned and replace Cap Some downward pressure may be needed to compress Gasket prior to rotating Cap clockwise 6 Lower Water Tank into Base positioning Water Tank over raised bump in Base Once in nested position water outlet val...

Page 11: ...tlet 2 To turn humidifier on press Power Button The LCD screen will illuminate when powered On and as settings are adjusted Once settings have been selected the LCD screen will dim 3 Select Mist Condition Fan Speed and desired Humidity Level or Continuous for a personalized experience The humidifier also offers two programmed settings Auto1 Continuous misting cool mist low fan speed Auto2 Continuo...

Page 12: ...nk See FILLING WATER TANK for instructions 2 Unscrew Cap 3 Unscrew Mineral Cartridge from Cap A Discard Cartridge 4 Install new Cartridge onto Cap Again before use soak cartridge in water for 24 hours Note The unit may take several minutes to create mist with the initial use of a new Mineral Cartridge 5 If storing unit empty Water Tank and reinstall Cap Replace Tank back into unit See STORAGE A Th...

Page 13: ...ghout the season or when algae mineral deposits or other particles begin to form 1 gal Water 1 tsp Chlorine Bleach 20 min TO CLEAN AND DISINFECT BASE 1 Turn humidifier Off and unplug Warning Do not submerge humidifier in water 2 Remove Water Tank and empty Tank along with Base Rinse with clean tap water 3 Mix solution of 1 teaspoon chlorine bleach and 1 gallon water Fill Base with solution wet all...

Page 14: ...essed air around the top outlet grill and side inlet grill Follow up using brush attachment on your household vacuum cleaner to vacuum top outlet grill and side inlet grill Wipe down entire surface with soft cloth Note If the humidifier is turned Off with water in Base and not turned back on for 8 hours or longer or if humidifier is not cleaned as recommended you may experience some growth of alga...

Page 15: ...our Vornado Ultrasonic Whole Room Humidifier operates If you operate your humidifier continuously which is recommended to maintain humidity all day it may need to be refilled with water every day Check the Water Tank to be certain that there is an adequate water supply for operation Allow for optimum airflow by keeping the grill unobstructed Ensure curtains and other items are far enough away from...

Page 16: ...set point When set humidity level is reached the unit will not produce mist until humidity level in the room drops below humidity set point Airflow is blocked Remove obstruction Unit settings are too low Set to High Output and Continuous Humidity for maximum humidity output Mineral Cartridge is no longer removing minerals from water Cartridge needs to be replaced See MINERAL CARTRIDGE Unit and Tra...

Page 17: ...cation repair by unauthorized repair center or use of non approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties The product warranty will be honored only on models that are being used in the country intended REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER VORNADO SHALL NOT BE LI...

Page 18: ...CL3 0458 R V00 Vornado Air LLC 415 East 13th Street Andover Kansas 67002 800 234 0604 vornado com ...

Reviews: