background image

9

English

HOW TO USE

Before use, check appliance for visible damage. DO NOT USE THIS HEATER if there is evidence of damage. If any damage is found, contact 
Vornado Air LLC at 1-800-234-0604.

1. 

Use integrated handle on 

back of heater for lifting 
and carrying. 

2.

 Position heater so airflow is 

not obstructed.

3.

 Plug power cord into standard 

grounded wall outlet.

4.

 Press Power button   and 

select Mode  . Red light on 
front of heater illuminates to 
indicate the heater is On. Next, 
set thermostat to highest setting 
by turning clockwise. When 
room reaches desired comfort 
level, turn thermostat slowly 
counterclockwise until heat 
cycles off. 

Summary of Contents for MVH

Page 1: ...model MVH vornado com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...2 English vornado com 800 234 0604 help vornado com we expect this product to be PERFECT if it s not WE will make it right ...

Page 3: ...3 English Important Safety Instructions 4 Safety Features 7 Controls 8 How to Use 9 Cleaning 10 Storage 11 Reset Heater 11 Troubleshooting 12 Warranty 13 CONTENTS ...

Page 4: ... not use this heater in an RV boat or during any application where battery power is converted to AC power Place this product at least 3 feet away on all sides from electrical outlets furniture pillows bedding papers clothes curtains and other objects that may cause or catch on fire Do not place the heater near a bed because objects such as pillows or blankets can fall off the bed and be ignited by...

Page 5: ...ny part of the unit including the cord and plug Only original replacement parts may be used Never use the cord as a handle or otherwise yank strain or stretch the power cord While the product is plugged in do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater Check your heater cord and plug connections A l...

Page 6: ... CLEANING instructions provided Do not open appliance housing while product is plugged in To avoid risk of shock all service and or repairs must be done by a Vornado Authorized Service Center DISPOSAL WARNING To reduce waste and environmental harm observe the following PACKAGE RECYCLING The packaging protects the appliance from transport damage The packaging materials are selected from the point o...

Page 7: ...on and power is restored AUTOMATIC SAFETY SHUT OFF SYSTEM If airflow becomes blocked power to heater is shut off to prevent overheating AUTOMATIC TIP OVER PROTECTION If tipped more than 10 degrees in any direction power is cut to heater FINGER FRIENDLY DESIGN Resists curious fingers COOL TOUCH CASE Safe to touch even on high heat setting ...

Page 8: ...8 English CONTROLS POWER On I Off O THERMOSTAT MODE High Heat III 1500 watts Medium Heat II 1125 watts or Low Heat I 750 watts ...

Page 9: ...on back of heater for lifting and carrying 2 Position heater so airflow is not obstructed 3 Plug power cord into standard grounded wall outlet 4 Press Power button and select Mode Red light on front of heater illuminates to indicate the heater is On Next set thermostat to highest setting by turning clockwise When room reaches desired comfort level turn thermostat slowly counterclockwise until heat...

Page 10: ...ccumulated dust off the Front Outlet Grill 3 Use brush attachment on household vacuum cleaner to vacuum any accumulated dust off Air Inlets on sides of heater 4 Wipe down the entire heater with a soft dry cloth You should periodically blow out the heater with pressurized air to keep heat element and motor clear of dust hair and debris that can build up inside the heater as it moves air during use ...

Page 11: ...cur when the inlets or outlet are blocked If this happens the safety shut off system cuts power to the heater and you must manually reset the heater 1 Power heater off then unplug power cord 2 Remove any obstructions 3 Wait 5 10 minutes allowing heater to cool down 4 Plug in power cord and place heater in desired position 5 Press Power button On Your Vornado Heater should now function normally Not...

Page 12: ...vel surface See SAFETY FEATURES Unit is damaged or in need of repair Cease usage and unplug Contact Consumer Service for assistance Ensure unit is set to High Heat and thermostat is set to highest temperature setting Close all doors and windows to trap heat Allow unit to fully circulate heat throughout room may take several minutes Press the Power button Off and unplug unit A cylindrical plunger i...

Page 13: ...fication repair by unauthorized repair center or use of non approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties The product warranty will be honored only on models that are being used in the country intended REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER VORNADO SHALL NOT BE ...

Page 14: ...CL3 0446 R V03 Vornado Air LLC 415 East 13th Street Andover Kansas 67002 800 234 0604 vornado com ...