Ceramic Master E20 en v1
14
8. TECHNICAL DATA
1. Electrical supply
2.
Power consumption
2.1. Furnace with vacuum pump
2.2. Furnace without vacuum pump
3. Category of overtension
4. Vacuum pump data
4.1. Suction capacity
4.2. Regulated vacuum level
5. Maximal firing temperature
6. Effective firing chamber dimensions
7. Overall dimensions of closed furnace:
7.1. Width
7.2. Length
7.3. Height
8. Model Weight
9. mber of programs
10. Working temperature
11. Level of environment pollution
12. The device is designed for usage in normal dental
premises up to 2000 m altitude above sea level.
13. The maximum relative humidity of the air must
be 80% for temperatures up to 31°С, decreasing
lineally to 50% relative humidity for temperature
40°С.
14. Working modes
14.1. Programming mode
Programming of the parameters is fully
described in chapter 7. PROGRAMMING.
14.2. Working mode
It shows the number of the executed program
and the parameters’ value of the ongoing
program phase.
The values of all parameters could be seen if
you use the Multi Functional Rotary Knob
MFK
.
~230 V, ±10%, 50/60Hz
1700 W
1550 W
ІІ
22 l/min
0,1 to 0,9 bar
1200°С
Ф 95 мм; h 60 мм
265 мм
370 мм
565 мм
20 кg
203
5°С - 40°С
2