6
C
K
Install bottom adjusting screw through bottom
rod and install bottom retaining clip and locking
screw (Figure 2).
With top latch bolt still retracted, adjust bottom
rod so latch bolt clears floor and bottom strike.
Close door and check bottom latch bolt for dead locking.
After bottom rod is fully adjusted per steps
11 and 12, turn bottom locking screw in against
flat on adjusting screw. Do not over-tighten.
ADJUST RODS
Open door and release top
latch bolt as shown (Figure 1).
Remove bottom locking
screw and retaining clip
(Figure 2).
Disconnect bottom vertical
rod by removing bottom
adjusting screw.
Loosen top locking screw.
Rotate top adjusting
screw clockwise until top
latch bolt is fully extended
(Figure 1).
Depress pushbar and release.
Make sure top latch bolt stays
retracted as shown.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Check device operation by opening and closing
door several times from the outside.
Redo adjustment procedure if :
- Top latchbolt is not held retracted
- Bottom latchbolt does not clear
floor and bottom strike
14.
15.
Bottom
latch bolt
(clears floor
and strike)
Figure 3
Figure 4
Top latch bolt
Shown fully
extended
Figure 1
Latch bolt retracted
(flush with latch case)
Figure 2
Bottom
adjusting
screw
Top
locking
screw
Top
adjusting
screw
Bottom
locking
screw
Check top latch bolt for deadlocking
(latch bolt should not push in).
Turn top locking screw in against flat on
adjusting screw. Do not over-tighten.
Install end cap and center case covers.
Bottom
retaining
clip
Remove protective
film from pushbar