Calibration, lower gear case factory
setting
Volvo Penta IPS units are always calibrated when they
leave the factory or warehouse. Factory setting cali-
bration is only required when a unit has been
exchanged or when an important part of the system
has been changed, e.g. a drive leg or a position indi-
cator/resolver (part of the steering system).
The calibration routine is carried out to align the end
positions of the port and starboard drive legs.
NOTICE!
A complete Volvo Penta IPS drive leg cali-
bration procedure always begins with a lower gear
case factory setting calibration.
Connect 3887101 Break-out box (
1
) to the engine
diagnostics connectors. Also connect
3838619 VODIA, diagnostic tool (
2
) to the switch box.
The box allows switching between drive legs during
work progress.
CONNECTED
SELECTED
DATA
POWER
MADE IN SWEDEN
3887101
CONNECTED
SELECTED
DATA
POWER
MADE IN SWEDEN
3887101
CONNECTED
SELECTED
DATA
POWER
MADE IN SWEDEN
3887101
P0008760
VODIA
VODIA
VODIA
1
2
1
1
2
2
Calibration and Settings, IPS Calibration
47704162 10-2014 © AB VOLVO PENTA
143