V1022266
4. Open the bleeder nipple on the cylinder head's leading edge and use an air nozzle in the fuel's inlet channel to lead
out the fuel.
NOTE!
Collect the excess fuel in a container.
5. Remove the hose from the oil trap and remove the valve cover.
NOTE!
Do not use a nut runner since the studs bolts may come loose from the cylinder head and damage electrical cables
and valve cover.
Figure 2
V1022264
6. Remove the unit injectors' electrical connections.
7. Remove the IEGR control valve's electrical connections and wipe clean around the control valve.
8. Remove the valve cover's stud bolt located in front of the IEGR control valve.
Figure 3
Stud bolt
9. Remove the bolts for the IEGR control valve. Remove the control valve and the pipe between the valve and the