Instrument panels
Display unit
35
Setting operating speed (raised speed)
(optional equipment)
1 Press the engine key.
2 Browse with the arrow down key to the screen for operating
speed.
3 Press the select/acknowledge key.
4 Browse with the arrow keys to the required setting. (The setting
procedure may at any time be interrupted with the ESC key.)
The range for the operating speed is 800–1600 rpm.
Each step represents 50 rpm. (The range can be altered with
VCADS Pro.)
5 Press the select/acknowledge key.
Zero setting cycle counter
1 Press the ESC key.
2 Press the arrow down key to the screen which shows values
before the zero setting.
3 Press the select/acknowledge key. The numerals are shown in
reverse image (The zero setting procedure may at any time be
interrupted with the ESC key.)
4 Acknowledge with the select/acknowledge key.
Acknowledging service interval
1 Press the service key.
2 Press the select/acknowledge key. The numerals are shown in
reverse image (The acknowledgement may at any time be
interrupted with the ESC key.)
3 Acknowledge by first pressing down the service key and then
within five seconds pressing down the select/acknowledge key.
4 The next interval (scheduled service) is shown next to the
service symbol and the count-down restarts.
1044596