Measurement
range
Resolution
Behaviour
Diode test
0.001 V
Flux voltage
0.5 -0.8 V
Measurement voltage: c. 3.3 V
Capacity measurement
Connect the plug of the black
test lead in the “COM” connect-
or.
Connect the plug of the red test
lead in the “V” connector.
Select the resistance measure-
ment range “Ω” using the rotary
switch.
Select capacity measurement
using the “SELECT” button.
Place the measurement probes
on the measurement object.
The capacity of the measure-
ment object will be displayed in
mF, μF or nF.
WARNING
Switch off the voltage in the test circuit and discharge all the capaci-
tors present there. Voltages in the test circuit falsify the measure-
ment result and can destroy the measuring instrument. Perform
voltage measurement on the component investigated before every
measurement; if necessary, discharge it via a highly resistive re-
sistance (e.g. 100 kΩ). Never short circuit a capacitor! Capacitors
can store large quantities of energy, which if discharged suddenly,
can cause electric shocks, arcing and fire.