VOLTIMA VSI/VST Series
83
Function
Explanation
Standard
Setting
Setting
Options
Output Voltage
Here the desired alternating
voltage can be set.
Note:
Only if the
requirement calls for a
different AC voltage!
230V
200V/220V
230V/240V
RCD Test
Here the function of the
integrated fault current
circuit breaker can be tested.
Not
Available
Not
Available
Last Error Code
Display of the last error
codes.
Available
Available
Battery Capacity
Specifies the battery capacity
in Ah connected to the
inverter. The value in Ah is
used to calculate the input
current and the remaining
runtime. This function is only
possible in conjunction with
a connected measuring shunt
(Current-Sensor).
90Ah
90Ah - 540Ah
(at 30Ah intervals)
Power-Saving Mode
-
Sleep mode
If the inverter does not
detect a load on the inverter
output for at least 10
minutes, the device enters
Power-Saving Mode.
The LED flashes green.
ON
ON/OFF
Low Voltage Cut-off
If the battery voltage drops
to the set value on
the
device, the inverter is
disconnected from the
battery.
10.0V
9.5V - 11.5V
(at 0.5V intervals)
Output Frequency
Here the desired output
frequency is set on the
device.
Note:
Change only if the
application requires a
different output frequency.
50hz
50Hz/60Hz