Voltek 10-00474 Owner'S Manual Download Page 8

Inverter runs small 

loads but not large 

ones. 

Low voltage battery 

Charge the battery 

Water entered

 

 

Water entered the unit 

Disconnect the inverter and 

wipe immediately with a dry 

cloth, or permanent damage can 

occur. 

Alarm is sounding 

Low voltage shutdown or 

thermal shutdown has 

occurred. 

Allow unit to cool. Improve air 

circulation around unit. Locate 

unit to a cooler environment. 

Reduce load if continuous 

operation is required. 

Measured inverter 

output is too low 

Standard  “average-reading” 

AC voltmeter used to 

measure output voltage, 

resulting in an apparent 

reading 5 to 15V too low. 

Inverter’s  “modified sine wave” 

output requires “true RMS” 

voltmeter for accurate 

measurements. 

Battery voltage is too low 

Recharge battery 

Battery run time is 

less than expected 

AC product power 

consumption  is higher than 

rated. 

Use a larger battery to make up 

for increased power 

requirement. 

Battery is old or defective. 

Replace battery 

Battery is not being properly 

charged. 

Some chargers are not able to 

fully recharge a battery. Make 

sure you use a powerful charger. 

6. Specifications   

 

a) AC Power Output   

Model

 

200W

 

400W

 

750W

 

AC output voltage 

 

125V AC 

(104V)

 

125V AC 

(104V)

 

125V AC 

(104V)

 

Continuous AC 

output power 

 

200W 

400W

 

750W 

Maximum AC 

output surge power

 

500W 

600W 

 

800W 

AC output 

frequency(nominal)

 

59~61Hz 

59~61Hz 

59~61Hz 

AC output 

waveform

 

Modified   

sine wave

 

Modified 

sine wave

 

Modified 

sine wave

 

Summary of Contents for 10-00474

Page 1: ...risk of injury please read this instruction manual and retain for future reference Should you have any questions or need any support please contact us at www voltec industries com Copyright 2009 VOLTE...

Page 2: ...low Warning The inverter produces the same AC power as normal household outlets and thus has a shock hazard Please do not allow children to use the inverters unattended Be sure that there is at least...

Page 3: ...will damage the inverter Failure to follow these safety guidelines may result in personal injury and or the damage to the unit It may also void the warranty 3 Features a LED Indicator Models 100W 300...

Page 4: ...Ventilation Openings The high speed cooling fan protects the inverter from over heating And the ventilation openings should be kept clear 11 Additional Protective Features a Over Input Voltage Shut Of...

Page 5: ...n the power inverter is not in use disconnect the DC cable clips from the battery to prevent unintended battery discharge Caution As the battery is used its voltage begins to fall When the inverter se...

Page 6: ...D Player VCR 35 13 71 Electric Knife 85 5 65 PSP 16 30 00 Nintendo DS 12 40 00 Rechargeable Electric Knife 10 48 00 Household Battery Chargers 15 32 00 2 way Radios 10 48 00 5 LCD TV 10 48 00 BlackBer...

Page 7: ...c Reference Chart PROBLEM CAUSE SOLUTION No power no indicator Battery is defective Replace battery Blown fuse Check and replace fuse Lose cable connections Check the connection to the battery Tighten...

Page 8: ...rter s modified sine wave output requires true RMS voltmeter for accurate measurements Battery voltage is too low Recharge battery Battery run time is less than expected AC product power consumption i...

Page 9: ...e 5V DC c DC Power Specifications Model 200W 400W 750W DC input voltage range 11 0 15 0V DC 11 0 15 0V DC 11 0 14 5V DC Battery drain with no AC load 0 35A at a 12V input 0 5A at a 12V input 0 5A at a...

Page 10: ...2V DC Battery drain with no AC load 0 6A at a 12V input 0 6A at a 12V input 1 A at a 12V input 1 A at a 12V input Low battery alarm trigger point 11 0 3VDC 11 0 3VDC 11 0 3VDC 11 0 3VDC Low battery s...