Do not connect the unit to any utility power distribution systems or branch circuits. 

 

Do not use the inverter in temperatures over 104(40

) or under 32(0

). 

 

Caution 

Do not use the unit on the following items: 

 

Small nickel-cadmium battery-operated appliances such as flashlights, razors and nightlights 

 

Battery chargers for battery packs used in hand power tool that have a warning label indicating dangerous 

voltages are present at the battery terminals. 

Caution – 2000W and 3000W 

When using ABOVE 1000W, please make sure you use the same standard cable kits and same standard battery or 

battery kits. Failure to do so will damage the inverter. 

 

Failure to follow these safety guidelines may result in personal injury and/or the damage to the unit. It may 

also void the warranty. 

3. Features 

a) LED Indicator Models – 100W – 3000W 

 

DC Input Panel 

 

1 Black terminal – 

negative DC power flow 

 

2 Cooling Fan and Ventilation Openings - 

protects the inverter from over-heating.     

3 Red terminal - 

positive DC power flow 

 

 
 

Indicators 

4 Green LED Indicator – 

indicates the inverter has power.   

5 Red LED Indicator— 

warns that the inverter has shut down due to low/high input voltage   

6 Power Button — 

press to activate the unit 

 
 
 

AC Outlet Panel

 

7 AC Outlets - 

receptacles for

 

120V AC products with a total continuous power equal to the wattage (W) of your 

inverter. 

8 USB Port

 - Offer 5V power for USB equipment. 

9

 

Ventilation Openings

 – never cover the ventilation openings. 

 

 
 

Summary of Contents for 10-00474

Page 1: ...risk of injury please read this instruction manual and retain for future reference Should you have any questions or need any support please contact us at www voltec industries com Copyright 2009 VOLTE...

Page 2: ...low Warning The inverter produces the same AC power as normal household outlets and thus has a shock hazard Please do not allow children to use the inverters unattended Be sure that there is at least...

Page 3: ...will damage the inverter Failure to follow these safety guidelines may result in personal injury and or the damage to the unit It may also void the warranty 3 Features a LED Indicator Models 100W 300...

Page 4: ...Ventilation Openings The high speed cooling fan protects the inverter from over heating And the ventilation openings should be kept clear 11 Additional Protective Features a Over Input Voltage Shut Of...

Page 5: ...n the power inverter is not in use disconnect the DC cable clips from the battery to prevent unintended battery discharge Caution As the battery is used its voltage begins to fall When the inverter se...

Page 6: ...D Player VCR 35 13 71 Electric Knife 85 5 65 PSP 16 30 00 Nintendo DS 12 40 00 Rechargeable Electric Knife 10 48 00 Household Battery Chargers 15 32 00 2 way Radios 10 48 00 5 LCD TV 10 48 00 BlackBer...

Page 7: ...c Reference Chart PROBLEM CAUSE SOLUTION No power no indicator Battery is defective Replace battery Blown fuse Check and replace fuse Lose cable connections Check the connection to the battery Tighten...

Page 8: ...rter s modified sine wave output requires true RMS voltmeter for accurate measurements Battery voltage is too low Recharge battery Battery run time is less than expected AC product power consumption i...

Page 9: ...e 5V DC c DC Power Specifications Model 200W 400W 750W DC input voltage range 11 0 15 0V DC 11 0 15 0V DC 11 0 14 5V DC Battery drain with no AC load 0 35A at a 12V input 0 5A at a 12V input 0 5A at a...

Page 10: ...2V DC Battery drain with no AC load 0 6A at a 12V input 0 6A at a 12V input 1 A at a 12V input 1 A at a 12V input Low battery alarm trigger point 11 0 3VDC 11 0 3VDC 11 0 3VDC 11 0 3VDC Low battery s...