FEATURES

 

 

 

3 Stage charge 

 

2 Stage charge for LiFePO4 batteries. 

 

9-32V input for either 12V or 24V input 

 

Charge AUX batteries from long distance charge source. 

 

Ignition Control feature. 

 

Low Voltage Cut Off Protection for starting battery. 

 

Auto Reset Input Under Voltage Protection. 

 

Auto Reset Output Over Voltage Protection. 

 

Auto Reset Over Temperature Protection. 

 

Auto Reset Overload Protection (C.C.) with constant current at decreased output voltage. 

 
 
PROTECTIONS:

 

 

 

Input under voltage protection 

 

Output Over voltage protection 

 

Overload protection 

 

Over temperature protection 

 

TROUBLESHOOTING GUIDE:  
IT IS RECCOMENDED THAT THE UNIT BE CHECKED BY A QUALIFIED PERSON. READ ALL INSTRUCTIONS AND 
NOTES CAREFULLY BEFORE CALLING ELECTRO PARTS AUST PTY LTD.  

ALL MEASUREMENTS MUST BE TAKEN AT TERMINALS OF UNIT NOT AT BATTERIES.  

 

NO OUTPUT:

 

SOLUTION: 

 

IGNITION MODE: If there has been a Low Voltage Disconnect condition, there will be no output until the input 
Voltage reaches above Low Voltage Reconnect, even if the ignition source has been turned off and back on again. 

 

Check charging status mode if solid green and output Voltage is higher than 12.6V Unit will be in float mode. 

 

 

Load the output battery to check that current flows.

 

 

Check the input and output connections. 

 

Check the input Voltage and compare to Start Charge setting and low Voltage Reconnect. 

 

Check what mode the unit is in.  Unit may be in IGNITION MODE, check if Input Voltage is above set point.

 

 

Check all wires are connected properly without a loose connection including ignition pin.

 

 

Check input and output fuses inside.

 

FAULT LIGHT: 

SOLUTION:  

 

Fault will be on if there is no connection or Voltage to input but there is to connection to output. 

 

Fault will be on if the input Voltage is below the start charge Voltage. 

 

Fault will be on if the input Voltage is below Low Voltage Disconnect. 

 

Fault is on, If Low Voltage Disconnect occurs and the input is still not above Low Voltage Reconnect. 

 

Check that input Voltage is above the start charge setting.

 

 

Check that the input Voltage is above the Low Voltage Disconnect.

 

 

If input has reached below Low Voltage Disconnect, check that the input is above Low Voltage Reconnect.

 

 

Check all connections, fuses or circuit breakers. 

 

Check that input and output are wired up correctly at unit. 

 

 

Summary of Contents for SBC-5925

Page 1: ...32V input range suitable for 12V or 24V input to 12V output but NOT 24V output 70 mA current draw on input side when not charging and unit on in AUTO START MODE CHARGING STATUS LED BULK MODE FAST FLASH VOLTAGE WILL KEEP RISING UNTIL ABSORPTION VOLTAGE IS REACHED SOFT START FAST FLASH IF IN FLOAT OUTPUT IS 1 15A UNTIL BULK CAN BE REACHED THIS IS IF OUTPUT BATTERY IS LOW OR THERE IS A HIGH LOAD ABSO...

Page 2: ...both input and output to the unit 3 Unit can take input from either a 12V or 24V vehicle 4 Or you can take a Voltage signal 12V or 24V from any source 5 The unit will always start in bulk mode when connected or mode changed refer to Charging status LED 6 1 min delay for Start Charge 10 sec delay for Stop Charge in AUTO START MODE 10 sec delay in IGNITION MODE 7 IGNITION MODE ONLY Apply 9 32V to ig...

Page 3: ...N MODE or OK FOR VEHICLES 12 8V CHARGE OR OK FOR BATCH STARTING WITH SERIAL s 1516 IGNITION MODE 1 To change to IGNITION MODE supply 9 32V to the ignition pin at any time even in AUTO START MODE 2 There is no need to Press and hold the Battery Select button for this mode 3 THE SETTING IS SAVED UNTIL THE UNIT IS RESET TO AUTO START MODE TERMINAL BLOCK V IN The V pin has the same voltage as the inpu...

Page 4: ...d back on again Check charging status mode if solid green and output Voltage is higher than 12 6V Unit will be in float mode Load the output battery to check that current flows Check the input and output connections Check the input Voltage and compare to Start Charge setting and low Voltage Reconnect Check what mode the unit is in Unit may be in IGNITION MODE check if Input Voltage is above set po...

Page 5: ... keep the input Voltage above the Cut in setting see below for solution This is not a fault of the unit The unit starts in bulk mode AND input is below Cut out Voltage as the input and output are paralleled the overall input Voltage will drop depending on the charge source This is caused by either low voltage or low current input or very flat battery or high load on output Check input Voltage and ...

Reviews: