background image

N.  Specifications 
 

Model 

BC-1240P-1AP 

Output 

Output (Charge) Voltage Selections 

Absorption 

Float 

WET 

14.4V 

13.5V 

LiFePO4 

14.6V 

13.6V 

AGM 

14.3V 

13.2V 

GEL 1 

14.1V 

13.7V 

GEL 2 

14.3V 

13.8V 

CALCIUM 

15.1V 

13.8V 

User Define 1 

12V - 16V 

User Define 2 

12V - 16V 

Equalization 

15.5V 

Maximum Output Charging Current (Continuous) 

40A 

Recommended Battery Capacity Range 

15 – 400AH 

Soft Start Bulk Charge 

Battery Voltage to Trigger (cut-in) Soft Start 
Bulk Charge Mode 

<12.3V 

Soft Start Bulk Charge Current (Current Limit) 

1/2 of the charging current 

 

Ripple and Noise (Peak to Peak) 

<200mV 

Efficiency at Maximum Power (230V) 

>83% 

 

Dual Bank Charging (Battery must be of same type) 

Yes 

Input 

AC Voltage Range 

200 – 240V 50Hz~ 

AC Current at Full Load (230V) 

3.5A 

Protection 

Overload 

90-110% Rated Output Current or 50% Rated Output Current (Soft Charge) 

Protection  Type:  Constant  Current  Limiting,  recovers  Automatically  after 
Fault Condition is Removed. 

Short Circuit 

Recovers Automatically if Fault Condition is Removed within 20 seconds 

Otherwise the charger will shutdown until re-start the charger again 

Reverse Polarity 

Car Blade Fuse 

Over Temperature 

Protection Type: Shut Down 

OVP Output Over Voltage 

Yes 

Cooling 

Cooling Method 

Thermostatic, Variable Speed Fan 

Indicators 

4-Stage Battery Charger   

Yes 

Charge Phase Bulk / Absorption / Float 

Yes 

Fault Mode 

Yes 

Over Temp   

Yes 

Charger ON 

Yes 

Fuses 

AC Fuses at IEC AC Power Socket 

T4A slow blow 

DC Car Blade Fuse at Front Panel 

30Ax2 

Accessories 

Supplied Accessories 

Remote Temperature sensor, ac cable, spare ac fuse at socket, one set of 
50 Amp Grey Connector Kit. 

Optional Accessory 

Remote Control Panel (Model:HBR-3100) 

Approvals 

Safety :   
CE: EN 60335     

SAA: AS/NZS 60335.1, AS/NZS 60335.2.29 
(Include clause 21.102 : vibration Test) 

Yes 

EMC: CE EN 55014; EMF: EN50366 

Yes 

Others 

Dimensions and Weight 

200x80x260mm ; 3.2kg 

Remarks 

All values are based on the standard ambient temperature 25°C and pressure 0.1Mpa. 

 
 
 

Summary of Contents for BC-1240P-1AP

Page 1: ...f a battery Never smoke use an open flame or create sparks near battery or charger during normal charging operation as Batteries may give out explosive gas Do not charge batteries in a sealed enclosur...

Page 2: ...and Calcium Calcium lead acid batteries There are two user programmable charging profiles for the professional users through USB port by personal computer In addition the programmed maintenance charge...

Page 3: ...Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at low high battery temperature B Using the charger 1 Check the supplied accessories AC c...

Page 4: ...ry charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loose paper sheet The air intake is at the bottom and air outlet at the back Make sur...

Page 5: ...s to Float Stage The max Absorption time is also controlled by the time in Bulk charge and battery type selected Stage 3 THE UO PHASE The constant voltage charging Float LED is ON In Float stage the b...

Page 6: ...ce the Voltage of each cell reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates You can use the Equalization Selection Switch 8 to perform the...

Page 7: ...duced output power OFF OFF ON At reduced output power as selected Indicates xx Power Set This is not a fault So no specific indication Battery over heat detected by remote temp sensor at 60 C Flashing...

Page 8: ...elect switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable...

Page 9: ...recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically if Fault Condition is Removed within 20 seconds Otherwise the charger will shutdown until re start the cha...

Page 10: ...level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mounted on BC char...

Page 11: ...output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle...

Page 12: ...r Level Display current output level 10 Software Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Eq...