62
Capacity
Range
Resolution
Accuracy
6.000 nF
0.001 nF
±(4% + 13)
60.00 nF
0.01 nF
±(4% + 6)
600.0 nF
0.1 nF
6.000 µF
0.001 µF
60.00 µF
0.01 µF
600.0 µF
0.1 µF
6.000 mF
0.001 mF
±10%
60.00 mF
0.01 mF
±13%
600 V overload protection
The accuracy values are valid when REL mode is enabled
Frequency “Hz” (electronic)
Range
Resolution
Accuracy
10 Hz–600.0 Hz*
0.1 Hz
±(0.1% + 5)
6.000 kHz
0.001 kHz
60.00 kHz
0.01 kHz
600.0 kHz
0.1 kHz
6.000 MHz
0.001 MHz
40.00 MHz
0.01 MHz
600 V overload protection
Signal level (without DC component):
≤100 kHz: 200 mV–30 Vrms
>100 kHz – <1 MHz: 600 mV–30 Vrms
≥1 MHz – <10 MHz: 1 V–30 Vrms
10 MHz – 40 MHz: 1.8 V–30 Vrms
* The frequency measuring range starts from 10 Hz
The standard measuring range includes frequencies ≤10 kHz.
Frequency “Hz” (electrical, sub-mode of A/AC and V/AC)
Range
Resolution
Accuracy
40–400 Hz
0.1 Hz
Not specified
Signal level: Sensitivity ≥30 Vrms
Summary of Contents for VC-740E