97
• Select the rechargeable battery programme "CHARGE"
with the buttons "INC" or "DEC".
The set rechargeable battery type is shown in the up-
per left of the display, and the rechargeable battery
programme next to it.
The value on the lower left shows the currently set charging current, the value at the lower
right shows the voltage or number of cells of the lead battery (in this example, a 6-cell lead
battery (6 x 2.0 V = 12.0 V)).
Use the buttons "INC" and "DEC" to select a different rechargeable battery pro-
gramme; use the button "BATT. TYPE/STOP" to return to the main menu.
• If the value for the charging current must be changed, push the "START/ENTER" button. The
charging current flashes. Change the charging current using the buttons "INC" and "DEC".
Keep the respective button pressed for quick adjustment.
The maximum possible charging current depends on the battery type and number of
cells. The max. charging capacity for output #1 is 100 W; 50 W are available for output
#2. The combined charging capacity (output #1 + #2) is max. 100 W.
• Confirm the set charging current with the "START/ENTER" button.
• The number of the cells in the lower right of the display flashes. Set the number of the cells
with the buttons "INC" and "DEC". Keep the respective button pressed for quick adjustment.
• Confirm the number of the cells by pressing the "START/ENTER" button.
• When no display is flashing anymore, start charging by keeping the "START/ENTER" button
pushed (approx. 3 seconds).
If the settings are wrong, or if the charger detects a problem, an audio signal is emit-
ted and the appropriate information is shown on the display. You can stop the warning
signal by pressing the "BATT. TYPE/STOP" button. The charger then returns to the
previous configuration menu.
The display shows, e.g., the following data while charging:
The rechargeable battery type is shown in the upper
left ("P" = lead battery), as well as the cell number; the
upper middle shows the charging current and the upper
right the current rechargeable battery voltage.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in
the middle the elapsed charging time and the charged capacity in mAh are displayed to the
right of this.
• Once the charging process has been completed, an audio signal is emitted (if it was not turned
off).
If you wish to cancel the charging process, push the "BATT. TYPE/STOP" button.
Pb CHARGE
1.0A 12.0V(6P)
P-6 1.0A 12.32V
CHG 022:45 00690
Summary of Contents for V-CHARGE 100 DUO
Page 16: ...16 8 Bedienelemente 4 3 5 6 7 1 2 8 9 10 11 12 13 14 15 16 17 18 19 ...
Page 74: ...74 8 Operating Elements 4 3 5 6 7 1 2 8 9 10 11 12 13 14 15 16 17 18 19 ...
Page 132: ...132 8 Éléments de commande 4 3 5 6 7 1 2 8 9 10 11 12 13 14 15 16 17 18 19 ...
Page 190: ...190 8 Bedieningselementen 4 3 5 6 7 1 2 8 9 10 11 12 13 14 15 16 17 18 19 ...
Page 234: ...234 ...
Page 235: ...235 ...