INTENDED USE

1. 

The power supply unit is intended for the connection and operation of low voltage loads with an operating 
voltage of 1.5 to 15 VDC via 4mm safety sockets. 
The current consumption of the connected consumer load must not exceed 1.5 A. If exceeded, the power 
supply unit may overload. If the power supply overloads, e.g. due to a short-circuit or excessive current draw, 
the output will be shut off to avoid damage. After removing the overload, the power supply unit can be put back 
into operation. 
The power supply unit complies with protection class 1. It is only approved for connection to a mains socket 
with protective earthing and a normal AC voltage of 230V 50Hz.

This product fulfils European and national requirements related to electromagnetic compatibility (EMC). 
CE conformity has been verified and the relevant statements and documents have been deposited at 
the manufacturer.

Unauthorised conversion and/or modification of the device are inadmissible because of safety and approval 
reasons (CE). Any usage other than described above is not permitted and can damage the product and lead to 
associated risks such as short-circuit, fire, electric shock, etc. Please read the operating instructions thoroughly 
and keep them for further reference.

SAFETY INSTRUCTIoNS

2. 

We  do  not  assume  liability  for  resulting  damages  to  property  or  personal  injury  if  the 
product has been abused in any way or damaged by improper use or failure to observe 
these operating instructions. The warranty/ guarantee will then expire!
The  icon  with  exclamation  mark  indicates  important  information  in  the  operating 
instructions. Carefully read the whole operating instructions before operating the device, 
otherwise there is risk of danger.

This device left the manufacture’s factory in a safe and perfect condition.
We kindly request the user to observe the safety instructions and warnings contained in these 
operating instructions to preserve this condition and to ensure safe operation. Please observe 
the following symbols:

Note! Read the operating instructions!

The product is CE compliant and meets the requirements of the current European 
and national guidelines.

Terminal for the internal protective earth conductor; this screw/contact must not be
unscrewed.

Only to be used in dry indoor areas.

Personal safety

The product is not a toy and should be kept out of reach of children!

• 

The power supply unit is not designed for application to human beings or animals.

• 

Product safety

The device must not be opened. When you open covers or remove parts – unless you can do 

• 

this by hand – parts carrying current can be exposed. Capacitors inside the device may still be 
charged, even if the device has been disconnected from all voltage sources.
Do also observe the safety and operating instructions of devices which you connect to the unit 

• 

as well as those you find in individual chapters of these operating instructions.
Never touch the device when your hands are wet or damp. There is the risk of a fatal electric 

• 

shock.
Power supply units and connected loads must not be operated unattended.

• 

Only use fuses of the rated type and current. It is absolutely prohibited to use repaired fuses.

• 

Avoid using uninsulated metallic leads.
In industrial facilities, the safety regulations laid down by the professional trade association for 

• 

electrical equipment and facilities must be adhered to.
Power supply units used at schools, training facilities, do-it-yourself and hobby workshops 

• 

should not be handled unless supervised by trained, responsible personnel.
The device will warm up during operation. Make sure sufficient ventilation is provided; the 

• 

housing  must  not  be  covered!  Do  not  touch  the  cooling  element  on  the  rear  side  during 
operation. Risk of burns!
Never turn on the device immediately after it has been brought from a cold room into a warm 

• 

one. Condensation water that forms might destroy your device. Leave the device switched off 
and wait until it has reached room temperature.

When used in conjunction with other devices, observe the operating instructions and safety 

• 

notices of  connected devices.
The product must not be subjected to heavy mechanical stress.

• 

The product must not be exposed it to extreme temperatures, direct sunlight, intense vibration, 

• 

or dampness.
Operation  under  unfavourable  ambient  conditions  is  not  permitted.  Unfavourable  ambient 

• 

conditions are:

Excessive humidity or dampness

 -

Dust and combustible gases, vapours or solvents.

 -

Thunderstorms or similar conditions such as strong electrostatic fields etc.

 -

If you have a reason to believe that the device can no longer be operated safely, disconnect 

• 

it immediately and secure it against being operated unintentionally. Safe operation must be 
presumed to be no longer possible if:

the device is visibly damaged,

 -

the unit no longer operates and

 -

if it has been stored for long periods of time under unfavourable conditions or

 -

if it has been subjected to considerable stress in transit.

 -

Miscellaneous

Repair works must only be carried out by a specialist/ specialist workshop.

• 

If  you  have  queries  about  handling  the  device,  that  are  not  answered  in  this  operating 

• 

instruction,  our  technical  support  is  available  under  the  following  address  and  telephone 
number: Voltcraft

®

, 92242 Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 723 8

oPERATING ELEMENTS

3. 

Power indicator

1. 

Power switch for switching the the device on (1=ON / 0=OFF)

2. 

4 mm safety socket „negative pole“ (-)

3. 

4 mm safety socket „positive pole“ (+)

4. 

Output voltage control for voltages ranging from 1.5 to 15 V

5. 

Analogue DC voltmeter

6. 

Cooling element (rear side); heats up during operation!

7. 

IEC inlet (rear side)

8. 

Mains fuse holder (rear side)

9. 

FUNCTIoNAL DESCRIPTIoN

4. 

The DC output of the power supply unit is electrically isolated and features protective separation from mains 
voltage. 
The output voltage can be adjusted from 1.5 V to 15 V DC using the voltage control (5); current limiting is not 
possible. The actual output voltage is shown in the moving coil instrument (6).The DC connection is possible 
via two coloured 4mm safety sockets (3 and 4). 
The power supply unit is cooled by convection; make sure sufficient ventilation and space is provided.

The  power  supply  unit  is  equipped  with  an  overload  protection  circuit.  This  circuit  is 
activated when the maximum permissible current is exceeded due to an overload or short 
circuit. It will electronically reduce the output voltage to avoid damage to the power supply 
unit.

Summary of Contents for PS-1152A

Page 1: ...n allen Spannungsquellen getrennt wurde Beachten Sie auch die Sicherheitshinweise und Bedienungsanleitungen der brigen Ger te die an das Ger t angeschlossen werden sowie in den einzelnen Kapitel diese...

Page 2: ...Reinigungsmittel Achtung Ziehen Sie immer den Netzstecker aus der Netzsteckdose bevor Sie das Ger t reinigen Sicherungswechsel 7 L sst sich das Netzger t nicht mehr einschalten so ist vermutlich die...

Page 3: ...ed unattended Only use fuses of the rated type and current It is absolutely prohibited to use repaired fuses Avoid using uninsulated metallic leads In industrial facilities the safety regulations laid...

Page 4: ...onnecting cables from the unit Pull the mains plug from the mains socket Using a suitable screwdriver depress the fuse holder 9 on the rear side a little and remove it with a quarter turn anti clockwi...

Page 5: ...ources de tension Respectez galement les consignes de s curit et les modes d emploi des autres appareils raccord s l appareil consid r ainsi que les diff rents chapitres du pr sent mode d emploi Ne to...

Page 6: ...ppareil Remplacement des fusibles 7 Lorsque le bloc d alimentation ne se laisse plus mettre en circuit le fusible de secteur est probablement d fectueux Afin de remplacer le fusible de secteur proc de...

Page 7: ...toestel van alle spanningsbronnen losgemaakt werd Let ook op de veiligheidsaanwijzingen en de gebruiksaanwijzing van de overige toestellen die aan dit toestel aangesloten worden evenals deze in de ho...

Page 8: ...altijd de netstekker uit het stopcontact voor u het toestel gaat reinigen Zekeringswissel 7 Wanneer het toestel niet meer aangaat dan is er waarschijnlijk een defecte netzekering Voor het wisselen va...

Reviews: