VOLTCRAFT PM-45 Operating Instructions Manual Download Page 4

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in 

electronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is 

prohibited. This publication reflects the technical status at the time of printing.

Copyright 2019 by Conrad Electronic SE. 

*1716077_V1_0319_02_hk_m_en

Setup

 Pay attention to the technical data. The permissible voltage of max. 10 V/DC and the 

permissible current of max. 2.4 A must not be exceeded.

The USB power meter adapter is used as an accessory for one or two multimeters. The adapter 

can be connected to a digital or analogue multimeter (not included) with suitable connectors.
•  Perform the current and voltage measurement simultaneously or separately. Connect the 

cables according to the connection options shown below.

•  Connect the test leads 

(7)

 to the connectors 

(2, 3, 4, 5)

 of the USB power meter adapter and 

to one or two multimeters (DMM or analogue). Make sure that the colour codings on the test 

leads and on the adapter (black and red) match.

•  Connect the USB-A plug 

(1)

 to the power supply (e.g. 5 V/DC power bank or USB power 

supply).

•  Connect a USB cable (not included) to the USB-A port 

(4)

 and the other end of the cable to 

your consumer (e.g. smartphone).

a) Voltage measurement

  

 

5 V/DC

 

 

DMM

v

V

C

A

OUT

IN

A

V

IN

OUT

DMM

Device

Power supply (e.g. USB power supply)

Test leads

USB power meter adapter

b) Current measurement

OUT

IN

A

V

IN

OUT

5 V/DC

 

 

DMM

c

V

A

mA

DMM

Device

Power supply (e.g. USB power supply)

Test leads

USB power meter adapter

c) Current and voltage measurement

OUT

IN

A

V

IN

OUT

 

 

DMM

v

c

V

A

DMM

c

V

A

mA

5 V/DC

2x DMM

Device

Power supply (e.g. USB power supply)

Test leads

USB power meter adapter

Care and Cleaning

•  Disconnect the product from the power supply and the connected devices before cleaning 

the product. 

•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may 

damage the case or cause the product to malfunction.

•  Use a dry, lint-free cloth to clean the product.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product according to 

the relevant statutory regulations.

You thus fulfil your statutory obligations and contribute to environmental protection.

Technical Data

Operating voltage ......................... 5 V/DC (max. 10 V/DC)
Operating current .......................... max. 2.4 A
Test leads ..................................... 4 pairs each with 4 mm plug (1x black, 3x red)
Cable length of the test leads ....... 118 cm each (including plug)
USB cable length .......................... 18 cm
Operating/storage conditions ........ -10 to +50 °C, <90% RH
Dimensions (L x W x H) ................ 114 x 35 x 26 mm (without USB cable)
Weight .......................................... 52 g

Summary of Contents for PM-45

Page 1: ...Ger te mit einer Spannung von 5 V DC max 10 V DC und einen Strom bis max 2 4 A ber ein Multimeter messen Eine Verwendung ist nur in geschlossenen R umen also nicht im Freien erlaubt Der Kontakt mit Fe...

Page 2: ...oder USB Netzteil Verbinden Sie ein USB Kabel nicht im Lieferumfang enthalten mit dem USB AAnschluss 4 und das andere Ende des Kabels mit Ihrem Verbraucher z B Smartphone a Spannungsmessung 5 V DC DM...

Page 3: ...or indoor use only Do not use it outdoors Contact with moisture e g in a bathroom must be avoided under all circumstances For safety and approval purposes do not rebuild and or modify this product Usi...

Page 4: ...not included to the USB A port 4 and the other end of the cable to your consumer e g smartphone a Voltage measurement 5 V DC DMM v V C A OUT IN A V IN OUT DMM Device Power supply e g USB power supply...

Page 5: ...pour un multim tre num rique ou analogique permettant de mesurer la tension ou le courant d un appareil connect L adaptateur peut mesurer des appareils ayant une tension de 5 V CC 10 V CC max et un co...

Page 6: ...smartphone a Mesure de la tension 5 V DC DMM v V C A OUT IN A V IN OUT Multim tre num rique Appareil Alimentation lectrique p ex alimentation USB Cordons de mesure Adaptateur de wattm tre USB 5 V CC b...

Page 7: ...r een multimeter meten Het product is alleen bedoeld voor gebruik in gesloten ruimtes dus gebruik buitenshuis is niet toegestaan Contact met vocht bijv in badkamers e d dient absoluut te worden vermed...

Page 8: ...SB voeding Sluit een USB kabel niet in de levering inbegrepen aan op de USB A aansluiting 4 en het andere uiteinde van de kabel aan op de verbruiker bijv smartphone a Spanningsmeting 5 V DC DMM v V C...